001-es BibID:BIBFORM132837
035-os BibID:(WOS)001588311300001 (Scopus)105018328533
Első szerző:Rácz Kálmán (igazságügyi rezidens)
Cím:Experimental Biomechanical study on the consequences of dashboard injury of the pelvis after total hip replacement / Rácz Kálmán, Simon Gábor, Győrfi Gyula, Kiss László, Bazsó Tamás, Csámer Loránd, Juhász Tamás, Gergely Péter Attila, Manó Sándor
Dátum:2026
ISSN:0937-9827
Megjegyzések:Fractures of the pelvic ring and acetabulum are caused by high-energy trauma, usually by traffic accidents. Acetabular fractures occur when a force drives the head of the femur against the acetabulum. As the prevalence of patients living with a total hip prosthesis (THR) increases, the chance of suffering periprosthetic acetabulum fractures also elevates. However, the injury threshold of forces resulting in a periprosthetic acetabular fracture is unknown. The study aimed to analyze the results of a dashboard injury on the acetabulum after total hip replacement through a head-on collision in an ex-vivo experiment. A cemented cup was implanted into hemipelves removed from cadavers, and a dashboard injury was simulated with an impact of a pendulum-like structure released from different heights. The impact energy increased until inflicting acetabular fracture. Eleven hemipelves were examined, of which five were male and six were female. The average force required to cause damage to the pelvis was 5852 N (3950-8386). Isolated acetabular component loosening was noticed with cement fracture in one case (at 5344 N force), acetabular cup loosening occurred combined with posterior column fracture in three cases (at 8386, 3950, 6295 N force), and acetabular cup loosening combined with acetabular floor fracture occurred in six cases (at 4305, 4573, 6531, 4707, 8174, 6117 N force). A combination of all three mechanisms occurred in one case: acetabular cup loosening, with posterior column and acetabular floor fracture at 5986 N force. The results of the ex-vivo experiment indicate that in a dashboard injury, at least around 4000 N force and 4 J impact energy is necessary to create a periacetabular fracture. The results suggest that a larger force is necessary for damage to occur in male pelvises: fractures occurred mostly below 5000 N force in female pelvises, while they occurred above 6000 N in most males.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Forensic pathology
Total hip replacement (THR)
Periprosthetic fracture
Traffic accident
Dashboard injury
Megjelenés:International Journal Of Legal Medicine. - 140 (2026), p. 559-565. -
További szerzők:Simon Gábor (1982-) (orvos) Győrfi Gyula (1982-) (orvos) Kiss László (1978-) (ortopéd sebész, traumatológus) Bazsó Tamás (1974-) (ortopéd sebész) Csámer Loránd (1983-) (biomechanika, mérnök) Juhász Tamás (1976-) (biológus, orvosbiológus) Gergely Péter (1974-) (igazságügyi orvosszakértő) Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök)
Pályázati támogatás:NKFIHK139396
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM047999
Első szerző:Szabó János (ortopéd sebész)
Cím:The biological and biomechanical comparison of two bulk bone graft techniques used in case of dysplastic acetabulum / János Szabó, Sándor Manó, Ádám Lőrincz, Gyula Győrfi, László Kiss, Zoltán Csernátony
Dátum:2014
ISSN:1633-8065 1432-1068
Megjegyzések:AbstractBackground The incorporation of bulk bone grafts in thereplacement of dysplastic acetabulum is determined by thebiological environment of the recipient site, the size of thecontact surface, and the stability of the osteosynthesis used.Based on these, the present study compares the Harrisacetabular plasty used routinely by us with the Radojevic?L-shaped graft technique.Methods For our measurements, we used 20 hemi-pelvisesremoved from 10 cadavers. In 10 cases, acetabularplasty according to Harris, in 10 cases Radojevic? L-plasty,was performed. The biological environment was analyzed;with geometric calculations, the contact surface wasdetermined, and with a material testing apparatus, theprimary stability of the osetosynthesis was measured. Forthe measurements, a new method was developed.Results The Radojevic? technique provides a better biologicalenvironment for graft ingrowth. The contact surfaceis nearly twice as much as in Harris plasty. No significantdifference was found in the primary stability of the osteosynthesisused. The deviation on the value of the stabilitymeasurements is explained by the differences in the bonequality of the cadavers used.Conclusions Based on the 3 aspects examined, the Radojevic? L-shaped graft technique has similar stability whencompared to the Harris acetabular plasty, but providesbetter biological circumstances and larger graft host bonecontact. Based on this, we started using the L-shapedtechnique in our department.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:European Journal of Orthopaedic Surgery and Traumatology. - 24 : 5 (2014), p. 679-684. -
További szerzők:Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök) Lőrincz Ádám Győrfi Gyula (1982-) (orvos) Kiss László (1978-) (ortopéd sebész, traumatológus) Csernátony Zoltán (1959-2023) (ortopéd sebész, traumatológus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM042724
Első szerző:Szabó János (ortopéd sebész)
Cím:Instrument development for acetabular roof plasty in case of dysplastic acetabular replacement / János Szabó, Sándor Manó, Ádám Lőrincz, Gyula Győrfi, László Kiss
Dátum:2012
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény hazai lapban
egyetemen (Magyarországon) készült közlemény
Megjelenés:Biomechanica Hungarica. - 5 : 1 (2012), p. 31-38. -