CCL

Összesen 7 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM131029
Első szerző:Egeresi Lilla (radiográfus)
Cím:Relationship Between Effective Dose, Alternative Metrics, and SSDE : experiences with Two CT Dose-Monitoring Systems / Egeresi Lilla Szatmáriné, Urbán László, Dankó Zsolt, Balázs Ervin, Berényi Ervin, Marosi Mária, Kiss János, Bágyi Péter, Képes Zita, Emri Miklós, Balkay László
Dátum:2025
ISSN:2075-4418
Megjegyzések:Background: We assessed the frequency and causes of discrepancies in CT dose indices such as dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose (ED), as calculated by CT dose-monitoring systems. Our secondary aim was to demonstrate the estimation of size-specific ED (SED) from the patients' dose records. Methods: The retrospective study included dosimetric data of 79,383 consecutive CT exams performed on two CT scanners. The following dose values were recorded from both the locally developed dose-monitoring system (DMS) and a commercial dose-monitoring program (DWTM): DLP, SSDE, and ED. Only the DMS provided bodyweight-corrected effective dose (SEDDMS) and the SED based on previous published data. Results: Without body-region-specific analysis, there were no tendentious differences between the DLP, ED, or SSDE values obtained from DWTM and DMS. However, the body region-based correlation revealed substantial differences between EDDMS and EDDW, primarily related to inadequate identification of the body. SSDE showed strong correlation to each anatomical category and CT device, except for the head region, where inadequate consideration of CT inclination was the reason for the biased SSDEDW value. Furthermore, by analyzing the SEDDMS, SSDE, and SED correlations, we concluded that SEDDMS is a promising figure for estimating the SED value. Conclusions: SED provides suitable supplementary size-specific dose data to SDDE and may be a preferable choice for estimating cumulative doses in routine radiological practice.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
computed tomography (CT)
dose-monitoring system (DMS)
effective dose (ED)
size-specific dose estimate (SSDE)
size-specific effective dose (SED)
Megjelenés:Diagnostics. - 15 : 13 (2025), p. 1-15. -
További szerzők:Urbán László (1960-) Dankó Zsolt (1991-) (fizikus) Balázs Ervin Berényi Ervin (1964-) (radiológus) Marosi Mária (1990-) (radiográfus) Kiss János (1992-) (fizikus) Bágyi Péter (1964-) (radiológus) Képes Zita (1991-) (orvos) Emri Miklós (1962-) (fizikus) Balkay László (1963-) (biofizikus)
Pályázati támogatás:TKP2021-NKTA-34
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM124304
Első szerző:Esze Regina (általános orvos)
Cím:The role of visceral and subcutaneous adipose tissue distribution determined by CT in the development of subclinical atherosclerosis in type 2 diabetes and obesit / R. Esze, L. Rajnai, L. Balkay, Z. Képes, S. Somodi, M. Emri, I. Garai, M. Káplár
Dátum:2021
Tárgyszavak:nem besorolt
egyéb
További szerzők:Rajnai Liliána Balkay László (1963-) (biofizikus) Képes Zita (1991-) (orvos) Somodi Sándor (1977-) (belgyógyász) Emri Miklós (1962-) (fizikus) Garai Ildikó (1966-) (radiológus) Káplár Miklós (1965-) (belgyógyász, diabetológus)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM121138
035-os BibID:(Scopus)85194278028 (WoS)001233268300001
Első szerző:Esze Regina (általános orvos)
Cím:Impact of Fat Distribution and Metabolic Diseases on Cerebral Microcirculation : a Multimodal Study on Type 2 Diabetic and Obese Patients / Regina Esze, László Balkay, Sándor Barna, Lilla Szatmáriné Egeresi, Miklós Emri, Dénes Páll, György Paragh, Liliána Rajnai, Sándor Somodi, Zita Képes, Ildikó Garai, Miklós Káplár
Dátum:2024
ISSN:2077-0383
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Journal of Clinical Medicine. - 13 : 10 (2024), p. 1-14. -
További szerzők:Balkay László (1963-) (biofizikus) Barna Sándor (1982-) (kutató orvos) Egeresi Lilla (1992-) (radiográfus) Emri Miklós (1962-) (fizikus) Páll Dénes (1967-) (belgyógyász, kardiológus) Paragh György (1953-) (belgyógyász) Rajnai Liliána Somodi Sándor (1977-) (belgyógyász) Képes Zita (1991-) (orvos) Garai Ildikó (1966-) (radiológus) Káplár Miklós (1965-) (belgyógyász, diabetológus)
Pályázati támogatás:2.1.1-15-2015-00609
GINOP
TKP2021-NKTA-34
Egyéb
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

4.

001-es BibID:BIBFORM091873
Első szerző:Esze Regina (általános orvos)
Cím:A viszcerális és szubkután zsírszöveti eloszlás szerepe a szubklinikus atherosclerosis kialakulásában 2-es típusú diabetes mellitusban és obezitásban / Esze Regina, Balkay László, Emri Miklós, Képes Zita, Rajnai Liliána, Somodi Sándor, Garai Ildikó, Káplár Miklós
Dátum:2020
ISSN:1217-372X
Tárgyszavak:Orvostudományok Klinikai orvostudományok konferenciacikk
folyóiratcikk
Megjelenés:Diabetologia Hungarica. - 28 : Suppl1 (2020), p. 23-24. -
További szerzők:Balkay László (1963-) (biofizikus) Emri Miklós (1962-) (fizikus) Képes Zita (1991-) (orvos) Rajnai Liliána Somodi Sándor (1977-) (belgyógyász) Garai Ildikó (1966-) (radiológus) Káplár Miklós (1965-) (belgyógyász, diabetológus)
Pályázati támogatás:2.1.1-15-2015-00609
GINOP
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

5.

001-es BibID:BIBFORM125214
035-os BibID:(scopus)85207360497
Első szerző:Kallos-Balogh Piroska
Cím:Multicentric study on the reproducibility and robustness of PET-based radiomics features with a realistic activity painting phantom / Kallos-Balogh Piroska, Vas Norman Felix, Toth Zoltan, Szakall Szabolcs, Szabo Peter, Garai Ildiko, Kepes Zita, Forgacs Attila, Szatmáriné Egeresi Lilla, Magnus Dahlbom, Balkay Laszlo
Dátum:2024
ISSN:1932-6203
Megjegyzések:Previously, we developed an "activity painting" tool for PET image simulation; however, it could simulate heterogeneous patterns only in the air. We aimed to improve this phantom technique to simulate arbitrary lesions in a radioactive background to perform relevant multi-center radiomic analysis. We conducted measurements moving a 22Na point source in a 20-liter background volume filled with 5 kBq/mL activity with an adequately controlled robotic system to prevent the surge of the water. Three different lesion patterns were "activity-painted" in five PET/CT cameras, resulting in 8 different reconstructions. We calculated 46 radiomic indeces (RI) for each lesion and imaging setting, applying absolute and relative discretization. Reproducibility and reliability were determined by the inter-setting coefficient of variation (CV) and the intraclass correlation coefficient (ICC). Hypothesis tests were used to compare RI between lesions. By simulating precisely the same lesions, we confirmed that the reconstructed voxel size and the spatial resolution of different PET cameras were critical for higher order RI. Considering conventional RIs, the SUVpeak and SUVmean proved the most reliable (CV<10%). CVs above 25% are more common for higher order RIs, but we also found that low CVs do not necessarily imply robust parameters but often rather insensitive RIs. Based on the hypothesis test, most RIs could clearly distinguish between the various lesions using absolute resampling. ICC analysis also revealed that most RIs were more reproducible with absolute discretization. The activity painting method in a real radioactive environment proved suitable for precisely detecting the radiomic differences derived from the different camera settings and texture characteristics. We also found that inter-setting CV is not an appropriate metric for analyzing RI parameters' reliability and robustness. Although multicentric cohorts are increasingly common in radiomics analysis, realistic texture phantoms can provide indispensable information on the sensitivity of an RI and how an individual RI parameter measures the texture.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Plos One. - 19 : 10 (2024), p. 1-24. -
További szerzők:Vas Norman Félix Tóth Zoltán Szakáll Szabolcs Szabó Péter Garai Ildikó (1966-) (radiológus) Képes Zita (1991-) (orvos) Forgács Attila (1985-) (fizikus) Egeresi Lilla (1992-) (radiográfus) Dahlbom, Magnus Balkay László (1963-) (biofizikus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

6.

001-es BibID:BIBFORM124313
Első szerző:Káplár Miklós (belgyógyász, diabetológus)
Cím:Impact of liver fat content on serum levels of plasminogen activator inhibitor-1, fibroblast growth factor 21 and cerebral microcirculation in type 2 diabetes and obesity / Miklós Káplár, Regina Esze, Liliana Rajnai, Zita Képes, László Balkay, Sándor Somodi, György Paragh, Mónika Katkó, Miklós Emri, Ildikó Garai, Péter Fülöp
Dátum:2024
Tárgyszavak:nem besorolt
egyéb
Megjelenés:EASD 2024 60th annual meeting, 10-13 September 2024, Virtual
További szerzők:Esze Regina (1987-) (általános orvos) Rajnai Liliána Képes Zita (1991-) (orvos) Balkay László (1963-) (biofizikus) Somodi Sándor (1977-) (belgyógyász) Paragh György (1953-) (belgyógyász) Katkó Mónika (1980-) (biológus) Emri Miklós (1962-) (fizikus) Garai Ildikó (1966-) (radiológus) Fülöp Péter (1974-) (belgyógyász, endokrinológus, lipidológus)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

7.

001-es BibID:BIBFORM117439
035-os BibID:(Scopus)85186741089 (WoS)001179422300026
Első szerző:Képes Zita (orvos)
Cím:Concomitant [18F]F-FAZA and [18F]F-FDG Imaging of Gynecological Cancer Xenografts : insight Into Tumor Hypoxia / Zita Kepes, Eva Hegedus, Tamas Sass, Csaba Csikos, Judit P. Szabo, Viktoria Szugyiczki, István Hajdu, Istvan Kertesz, Gabor Opposits, Jozsef Imrek, Laszlo Balkay, Ferenc Krisztián Kalman, Gyorgy Trencsenyi
Dátum:2024
ISSN:0258-851X
Megjegyzések:Background/Aim: Herein we assessed the feasibility of imaging protocols using both hypoxia-specific [18F]F-FAZA and [18F]F-FDG in bypassing the limitations derived from the non-specific findings of [18F]F-FDG PET imaging of tumor-related hypoxia. Materials and Methods: CoCl2-generated hypoxia was induced in multidrug resistant (Pgp+) or sensitive (Pgp-) human ovarian (Pgp- A2780, Pgp+ A2780AD), and cervix carcinoma (Pgp- KB-3-1, Pgp+ KB-V-1) cell lines to establish corresponding tumor-bearing mouse models. Prior to [18F]F-FDG/[18F]F-FAZA-based MiniPET imaging, in vitro [18F]F-FDG uptake measurements and western blotting were used to verify the presence of hypoxia. Results: Elevated GLUT-1, and hexokinase enzyme-II expression driven by CoCl2-induced activation of hypoxia-inducible factor-1? explains enhanced cellular [18F]F-FDG accumulation. No difference was observed in the [18F]F-FAZA accretion of Pgp+ and Pgptumors. Tumor-to-muscle ratios for [18F]F-FAZA measured at 110-120 min postinjection (6.2?0.1) provided the best contrasted images for the delineation of PET-oxic and PEThypoxic intratumor regions. Although all tumors exhibited heterogenous uptake of both radiopharmaceuticals, greater differences for [18F]F-FAZA between the tracer avid and non-accumulating regions indicate its superiority over [18F]F-FDG. Spatial correlation between [18F]F-FGD and [18F]F-FAZA scans confirms that hypoxia mostly occurs in regions with highly active glucose metabolism. Conclusion: The addition of [18F]F-FAZA PET to [18F]F-FGD imaging may add clinical value in determining hypoxic sub-regions.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Cervix xenotransplants
[18F]F-FAZA
[18F]F-FDG
GLUT-1 transporter
hexokinase enzyme-II
hypoxia-inducible factor-1
hypoxia
preclinical
positron emission tomography (PET)
ovarian xenotransplants
Megjelenés:In Vivo. - 38 : 2 (2024), p. 574-586. -
További szerzők:Hegedűs Éva (1978-) (biofizikus) Sass Tamás (1989-) (sebész szakorvos) Csikos Csaba (1997-) (orvos) Péli-Szabó Judit (1977-) (vegyész) Szugyiczki Viktória Hajdu István (1981-) (vegyész) Kertész István (1966-) (vegyész) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Imrek József (1980-) Balkay László (1963-) (biofizikus) Kálmán Ferenc K. (1978-) (vegyész) Trencsényi György (1978-) (biológus, biokémikus, molekuláris biológus)
Pályázati támogatás:Hungarian National Research, Development and Innovation Office (FK-134551 project)
Egyéb
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1