CCL

Összesen 2 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM098615
035-os BibID:(cikkazonosító)5902 (WoS)000706517100001 (Scopus)85116118060
Első szerző:Nagy Cynthia (1994-)
Cím:Development of an In-Line Enzyme Reactor Integrated into a Capillary Electrophoresis System / Nagy Cynthia, Szabo Ruben, Gaspar Attila
Dátum:2021
ISSN:1420-3049
Megjegyzések:The goal of this paper was to develop an in-line immobilized enzyme reactor (IMER) integrated into a capillary electrophoresis platform. In our research, we created the IMER by adsorbing trypsin onto the inner surface of a capillary in a short section. Enzyme immobilization was possible due to the electrostatic attraction between the oppositely charged fused silica capillary surface and trypsin. The reactor was formed by simply injecting and removing trypsin solution from the capillary inlet (similar to 1-2 cms). We investigated the factors affecting the efficiency of the reactor. The main advantages of the proposed method are the fast, cheap, and easy formation of an IMER with in-line protein digestion capability. Human tear samples were used to test the efficiency of the digestion in the microreactor.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Molecules. - 26 : 19 (2021), p. 1-14. -
További szerzők:Szabó Ruben (1998-) Gáspár Attila (1970-) (vegyész, kémikus)
Pályázati támogatás:K127931
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM106975
035-os BibID:(cikkazonosító)4540 (WoS)000833614900001 (Scopus)85137331295
Első szerző:Szabó Ruben
Cím:Determination of Phenolic Compounds by Capillary Zone Electrophoresis-Mass Spectrometry / Ruben Szabo, Attila Gaspar
Dátum:2022
ISSN:1420-3049
Megjegyzések:A CZE-MS method was developed for the determination of several phenolic compounds (phenolic acids, flavonoids). Since the analysis of these components necessitates the application of basic conditions for CZE separation and negative ionization mode for MS detection, the simplest choice was to use 0.5 M NH4OH and IPA:water (1:1 v/v%) as the background electrolyte and sheath liquid, respectively. The LOD values ranged between 0.004-1.9 mg/L showing that there are relatively large differences in the ionization (and chemical) features of these compounds. The precision data were better than 0.75 RSD% for migration times and were between 5-8 RSD% for peak areas. In order to test the applicability of the developed method, a honey sample was analyzed.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Molecules. - 27 : 14 (2022), p. 1-12. -
További szerzők:Gáspár Attila (1970-) (vegyész, kémikus)
Pályázati támogatás:K127931
OTKA
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:
Rekordok letöltése1