Magyar
Toggle navigation
Tudóstér
Magyar
Tudóstér
Keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Böngészés
Saját polc tartalma
(
0
)
Korábbi keresések
Összesen 1 találat.
#/oldal:
12
36
60
120
Rövid
Hosszú
MARC
Részletezés:
Rendezés:
Szerző növekvő
Szerző csökkenő
Cím növekvő
Cím csökkenő
Dátum növekvő
Dátum csökkenő
1.
001-es BibID:
BIBFORM018468
Első szerző:
Szalai Eszter (orvos)
Cím:
Evaluation of the Corneal Endothelium Using Noncontact and Contact Specular Microscopy / Szalai Eszter, Németh Gábor, Berta András, Jr. Módis László
Dátum:
2011
ISSN:
0277-3740
Megjegyzések:
To determine the difference between the endothelial cell density (ECD) and the morphologic measurements assessed with a recently developed noncontact specular microscope compared with a contact endothelial microscope. The agreement between the 2 independent operators was also investigated. Methods: The central corneal endothelium was examined in the right eyes of 41 healthy individuals using automated image analysis programs without correction for a noncontact specular microscope and a contact specular microscope (EM-3000, EM-1000; Tomey, Tennenlohe, Germany). The evaluated parameters such as ECD, average cell area (AVG), and coefficient of variation of the cell area were determined by 2 operators. Conversion factors were also considered to adjust the ECD values. Results: ECD measurements obtained with the noncontact instrument (2734 +/- 287 cells per square millimeter, first operator; 2726 +/- 282 cells per square millimeter, second operator) were significantly higher (P < 0.0001) in comparison with the contact microscope (2283 +/- 206 cells per square millimeter, first operator; 2274 +/- 242 cells per square millimeter, second operator) by both investigators. The contact specular microscope significantly over-estimated (P < 0.0001) AVG and coefficient of variation of the cell area values. Statistically significant correlation (P < 0.0001) was detected in ECD (r = 0.77, first operator) and AVG measurements (r = 0.72, first operator) between the 2 endothelial microscopes. Higher degree of agreement between operators was given when using the noncontact specular microscope compared with the contact instrument. Conclusions: The significant differences and the poor agreement between the automated software options disclosed that the 2 instruments cannot be used interchangeably.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:
Cornea. - 30 : 5 (2011), p. 567-570. -
További szerzők:
Németh Gábor (1975-) (szemész)
Berta András (1955-) (szemész, gyermekszemész)
Módis László (1964-) (szemész szakorvos, kontaktológus)
Internet cím:
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
Rekordok letöltése
1
Corvina könyvtári katalógus v8.2.27
© 2023
Monguz kft.
Minden jog fenntartva.