Magyar
Toggle navigation
Tudóstér
Magyar
Tudóstér
Keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Böngészés
Saját polc tartalma
(
0
)
Korábbi keresések
Összesen 1 találat.
#/oldal:
12
36
60
120
Rövid
Hosszú
MARC
Részletezés:
Rendezés:
Szerző növekvő
Szerző csökkenő
Cím növekvő
Cím csökkenő
Dátum növekvő
Dátum csökkenő
1.
001-es BibID:
BIBFORM034526
Első szerző:
Sutter, Martin A.
Cím:
Multimodal intraoperative monitoring (MIOM) during 409 lumbosacral surgical procedures in 409 patients / Sutter Martin A., Eggspuehler Andreas, Grob Dieter, Porchet Francois, Jeszenszky Dezsö, Dvorak Jiri
Dátum:
2007
ISSN:
0940-6719
Megjegyzések:
A prospective study on 409 patients who received multimodel intraoperative monitoring (MIOM) during lumbosacral surgical procedures between March 2000 and December 2005 was carried out. The objective of this study was to determine the sensitivity and specificity of MIOM techniques used to monitor conus medullaris, cauda equina and nerve root function during lumbosacral decompression surgery. MIOM has increasingly become important to monitor ascending and descending pathways, giving immediate feedback information regarding any neurological deficit during the decompression and stabilisation procedure in the lumbosacral region. Intraoperative spinal- and cortical-evoked potentials, combined with continuous EMG- and motor-evoked potentials of the muscles, were evaluated and compared with postoperative clinical neurological changes. A total of 409 consecutive patients with lumbosacral spinal stenosis with or without instability were monitored by MIOM during the entire surgical procedure. A total of 388 patients presented true-negative findings while two patients presented false negative and 1 patient false-positive findings. Eighteen patients presented true-positive findings where neurological deficit after the operation was intraoperatively predicted. Of the 18 true-positive findings, 12 patients recovered completely; however, 6 patients recovered only partially. The sensitivity of MIOM applied during decompression and fusion surgery of the lumbosacral region was calculated as 90%, and the specificity was calculated as 99.7%. On the basis of the results of this study, MIOM is an effective method of monitoring the conus medullaris, cauda equina and nerve root function during surgery at the lumbosacral junctions and might reduce postoperative surgical-related complications and therefore improve the long-term results.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:
European Spine Journal. - 16 : S2 (2007), p. 221-228. -
További szerzők:
Eggspuehler, Andreas
Grob, Dieter
Porchet, Françis
Jeszenszky Dezső (1954-) (idegsebész, ortopédus)
Dvorak, Jiri
Internet cím:
Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
Rekordok letöltése
1
Corvina könyvtári katalógus v8.2.27
© 2023
Monguz kft.
Minden jog fenntartva.