Magyar
Toggle navigation
Tudóstér
Magyar
Tudóstér
Keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Böngészés
Saját polc tartalma
(
0
)
Korábbi keresések
Összesen 1 találat.
#/oldal:
12
36
60
120
Rövid
Hosszú
MARC
Részletezés:
Rendezés:
Szerző növekvő
Szerző csökkenő
Cím növekvő
Cím csökkenő
Dátum növekvő
Dátum csökkenő
1.
001-es BibID:
BIBFORM046017
Első szerző:
Menzel, Matthias (sebész)
Cím:
Brain tissue oxygen monitoring for assessment of autoregulation : preliminary results suggest a new hypothesis / Menzel M., Soukup J., Henze D., Clausen T., Marx T., Hillman A., Mikó I., Grond S., Rieger A.
Dátum:
2003
ISSN:
0898-4921
Megjegyzések:
Brain tissue oxygen monitoring (P(ti)O2 (Neurotrend, Codman, Germany) was employed in addition to standard intracranial pressure (ICP) and cerebral perfusion pressure (CPP) monitoring in seven patients with severe neuronal damage of heterogeneous etiology. The correlation between P(ti)O2 changes and CPP fluctuations during periods of 30 minutes were analyzed, when CPP was above 70 mmHg and lower than 100 mmHg. A new ratio, the CPP-oxygen-reactivity (COR) index was calculated as COR=delta p(ti)O2 %/delta CPP%. The patient COR values were compared to those found in the brain of six noninjured anesthetized piglets. The analysis was performed to determine the significance of synchronous fluctuations of CPP and P(ti)O2, when CPP is above the lower threshold of autoregulation. The correlation between CPP variations and p(ti)O2 variations was found to be strong (R(mean)) = 0.74 +/- 0.17) in the patients and was weak in the uninjured animals (R(mean)) =0.38 +/- 0.43). The COR (mean) was 2.05 +/- 0.57 in patients and 0.78 +/- 0.6 in the animals. In the injured brain of our patients, we observed an unexpectedly close correlation between P(ti)O2 and CPP variations when CPP levels were within a therapeutically targeted range (70 to 100 mmHg). In a porcine model, we could not find this relationship in the noninjured brain. We speculate that an increased COR might be indicative for an impaired local pressure autoregulation. The preliminary data suggest that COR values above "1" might be pathologic. However, the reported sample sizes are too small to provide sufficient statistical power to justify inferential statistical analyses. As such, results are presented with descriptive statistics only, and should be regarded as a hypothesis.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:
Journal of Neurosurgical Anesthesiology. - 15 : 1 (2003), p. 33-44. -
További szerzők:
Soukup, Jens
Henze, Dirk
Clausen, Tobias
Marx, T.
Hillman, A.
Mikó Irén (1948-) (kutató sebész)
Grond, S.
Rieger, Andreas
Internet cím:
Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:
Saját polcon:
Rekordok letöltése
1
Corvina könyvtári katalógus v8.2.27
© 2023
Monguz kft.
Minden jog fenntartva.