Magyar
Toggle navigation
Tudóstér
Magyar
Tudóstér
Keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Böngészés
Saját polc tartalma
(
0
)
Korábbi keresések
Összesen 1 találat.
#/oldal:
12
36
60
120
Rövid
Hosszú
MARC
Részletezés:
Rendezés:
Szerző növekvő
Szerző csökkenő
Cím növekvő
Cím csökkenő
Dátum növekvő
Dátum csökkenő
1.
001-es BibID:
BIBFORM112171
035-os BibID:
(cikkazonosító)3861 (WoS)000997603500001 (Scopus)85160404373
Első szerző:
Kovács Ágnes Éva (mérnök)
Cím:
Comparative Analysis of Bone Ingrowth in 3D-Printed Titanium Lattice Structures with Different Patterns / Ágnes Éva Kovács, Zoltán Csernátony, Loránd Csámer, Gábor Méhes, Dániel Szabó, Mihály Veres, Mihály Braun, Balázs Harangi, Norbert Serbán, Lei Zhang, György Falk, Hajnalka Soósné Horváth, Sándor Manó
Dátum:
2023
ISSN:
1996-1944
Megjegyzések:
In this study, metal 3D printing technology was used to create lattice-shaped test specimens of orthopedic implants to determine the effect of different lattice shapes on bone ingrowth. Six different lattice shapes were used: gyroid, cube, cylinder, tetrahedron, double pyramid, and Voronoi. The lattice-structured implants were produced from Ti6Al4V alloy using direct metal laser sintering 3D printing technology with an EOS M290 printer. The implants were implanted into the femoral condyles of sheep, and the animals were euthanized 8 and 12 weeks after surgery. To determine the degree of bone ingrowth for different lattice-shaped implants, mechanical, histological, and image processing tests on ground samples and optical microscopic images were performed. In the mechanical test, the force required to compress the different lattice-shaped implants and the force required for a solid implant were compared, and significant differences were found in several instances. Statistically evaluating the results of our image processing algorithm, it was found that the digitally segmented areas clearly consisted of ingrown bone tissue; this finding is also supported by the results of classical histological processing. Our main goal was realized, so the bone ingrowth efficiencies of the six lattice shapes were ranked. It was found that the gyroid, double pyramid, and cube-shaped lattice implants had the highest degree of bone tissue growth per unit time. This ranking of the three lattice shapes remained the same at both 8 and 12 weeks after euthanasia. In accordance with the study, as a side project, a new image processing algorithm was developed that proved suitable for determining the degree of bone ingrowth in lattice implants from optical microscopic images. Along with the cube lattice shape, whose high bone ingrowth values have been previously reported in many studies, it was found that the gyroid and double pyramid lattice shapes produced similarly good results.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:
Materials. - 16 : 10 (2023), p. 1-16. -
További szerzők:
Csernátony Zoltán (1959-2023) (ortopéd sebész, traumatológus)
Csámer Lóránd (1983-) (mérnök)
Méhes Gábor (1966-) (patológus)
Szabó Dániel (1988-) (ortopéd sebész, traumatológus)
Veres Mihály (fizikus)
Braun Mihály (1966-) (vegyész, analitikus)
Harangi Balázs (1986-) (programtervező matematikus)
Serban Norbert
Zhang, Lei (1988-) (orvos)
Falk György
Soósné Horváth Hajnalka (1982-) (mérnök)
Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök)
Pályázati támogatás:
GINOP-2.2.1-15-2017-00055
GINOP
PD 137775
Egyéb
Internet cím:
Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
Rekordok letöltése
1
Corvina könyvtári katalógus v8.2.27
© 2023
Monguz kft.
Minden jog fenntartva.