Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device / László Módis, Ziad Hassan, Eszter Szalai, Zsuzsanna Flaskó, András Berta, Gábor Németh
Dátum:2016
ISSN:2222-3959 2227-4898
Megjegyzések:To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83?20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43?21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41?40.17mo (range: 11-128mo) after the keratoplasty and after 7.64?2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. ? 2016, International Journal of Ophthalmology (c/o Editorial Office). All rights reserved.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Corneal visualization Scheimpflug technology
Ocular biomechanics
Penetrating keratoplasty
Megjelenés:International Journal Of Ophthalmology 9 : 2 (2016), p. 235-238. -
További szerzők:Ziad, Hassan Szalai Eszter (1984-) (orvos) Flaskó Zsuzsanna Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1