CCL

Összesen 30 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM005828
Első szerző:Adolphi, R.
Cím:The CMS experiment at the CERN LHC / R. Adolphi, A. Fenyvesi, J. Imrek, J. Molnar, D. Novak, J. Palinkas, G. Szekely, N. Beni, A. Kapusi, G. Marian, B. Radics, P. Raics, Z. Szabo, Z. Szillasi, Z. L. Trocsanyi, G. Zilizi, The CMS Collaboration
Dátum:2008
Megjegyzések:The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 1034 cm-2 s-1 (1027 cm-2 s-1). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4? solid angle. Forward sampling calorimeters extend the pseudorapidity coverage to high values (|?| < 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
CMS kísérlet
Megjelenés:Journal of Instrumentation. - 0803 (2008), S08004. -
További szerzők:Fenyvesi András Imrek József (1980-) Molnár József (1954-) (villamosmérnök) Novák Dezső Imre (1971-) (villamosmérnök) Pálinkás József (1952-) (fizikus) Székely G. Béni Noémi (1980-) (kísérleti fizikus) Kapusi A. Marian Györgyi Radics Bálint Raics Péter (1944-) (fizikus) Szabó Zsolt (1963-) (fizikus) Szillási Zoltán (1971-) (fizikus) Trócsányi Zoltán (1961-) (fizikus) Zilizi Gyula (1965-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM077684
Első szerző:Bartók M.
Cím:Simulation of the dynamic inefficiency of the CMS pixel detector / M. Bartok, [Karancsi János] for the CMS collaboration
Dátum:2015
ISSN:1748-0221 1748-0221
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 10 : 05 (2015), 1-8. -
További szerzők:Karancsi János (1987-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM023308
Első szerző:Chatrchyan, S.
Cím:Time Reconstruction and Performance of the CMS Electromagnetic Calorimeter / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03011 (2010), p. 1-27. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

4.

001-es BibID:BIBFORM023306
Első szerző:Chatrchyan, S.
Cím:Alignment of the CMS Muon System with Cosmic-Ray and Beam-Halo Muons / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03020 (2010), p. 1-41. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

5.

001-es BibID:BIBFORM023304
Első szerző:Chatrchyan, S.
Cím:Performance Study of the CMS Barrel Resistive Plate Chambers with Cosmic Rays / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03017 (2010), p. 1-33. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

6.

001-es BibID:BIBFORM023300
Első szerző:Chatrchyan, S.
Cím:CMS Data Processing Workflows during an Extended Cosmic Ray Run / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03006 (2010), p. 1-43. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

7.

001-es BibID:BIBFORM023299
Első szerző:Chatrchyan, S.
Cím:Commissioning of the CMS Experiment and the Cosmic Run at Four Tesla / S. Chatrchyan, Trócsányi Zoltán, Pálinkás József, Ujvári Balázs, Zilizi Gyula, Szabó Zsolt, Béni Noémi, The CMS Collaboration
Dátum:2010
Megjegyzések:The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03001 (2010), p. 1-39. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) Béni Noémi (1980-) (kísérleti fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

8.

001-es BibID:BIBFORM023297
Első szerző:Chatrchyan, S.
Cím:Performance of the CMS Drift Tube Chambers with Cosmic Rays / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 microns, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03015 (2010), p. 1-47. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

9.

001-es BibID:BIBFORM023296
Első szerző:Chatrchyan, S.
Cím:Performance of CMS Hadron Calorimeter Timing and Synchronization using Test Beam, Cosmic Ray, and LHC Beam Data / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03013 (2010), p. 1-33. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

10.

001-es BibID:BIBFORM023170
Első szerző:Chatrchyan, S.
Cím:Precise Mapping of the Magnetic Field in the CMS Barrel Yoke using Cosmic Rays / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03021 (2010), p. 1-37. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

11.

001-es BibID:BIBFORM023171
Első szerző:Chatrchyan, S.
Cím:Performance and Operation of the CMS Electromagnetic Calorimeter / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03010 (2010), p. 1-39. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

12.

001-es BibID:BIBFORM023172
Első szerző:Chatrchyan, S.
Cím:Alignment of the CMS Silicon Tracker during Commissioning with Cosmic Rays / S. Chatrchyan on behalf of The CMS Collaboration
Dátum:2010
Megjegyzések:The CMS silicon tracker, consisting of 1440 silicon pixel and 15148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to a precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several methods, including the laser alignment system, and compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Journal of Instrumentation. - 5 : T03009 (2010), p. 1-41. -
További szerzők:Trócsányi Zoltán (1961-) (fizikus) Pálinkás József (1952-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Szabó Zsolt (1963-) (fizikus) The CMS Collaboration
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1 2 3