1.

001-es BibID:BIBFORM085799
Első szerző:Gáspár Attila (vegyész, kémikus)
Cím:Beam-injection flame-furnace atomic-absorption spectrometry (BIFF-AAS) with low-pressure sample-jet generation / Attila Gáspár, Harald Berndt
Dátum:2002
ISSN:1618-2642 1618-2650
Megjegyzések:Flame-furnace AAS (FF-AAS) comprises two individual, recently developed FAAS techniques remarkable for their high power of detection and the small amounts of sample required. One of these techniques is beam-injection flame-furnace AAS (BIFF-AAS), whereby the sample is introduced into a flame-heated atomization cell as a high-speed liquid jet. For the first time this sample-introduction beam has been generated at low pressure by use of a peristaltic pump and a special micro channel smooth jet nozzle developed for this application. Compared with standard FAAS a 7- to 17-fold improvement in the power of detection was obtained for six elements (Ag, Cd, Hg, Pb, Se, and Zn). The relative standard deviation (N=15) was between 0.7% and 3.4%. Sample volumes between 10 mL and 1 mL have been investigated. The applicability of the peristaltic pump for beam generation enables an optimum sampling mode for a variety of analytical tasks (continuous sample uptake, manual or automated, or different flow-injection modes). The method can also be regarded as a simple, effective interface between FIA techniques and flame AAS.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Flame AAS
Flame furnace AAS
Beam injection
Micro samples
Sample-jet generation
Megjelenés:Analytical and Bioanalytical Chemistry. - 372 : 5-6 (2002), p. 695-699. -
További szerzők:Berndt, Harald
Pályázati támogatás:FKFP 23/2001
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM085775
Első szerző:Gáspár Attila (vegyész, kémikus)
Cím:Analysis of submicroliter samples using micro thermospray flame furnace atomic absorption spectrometry / Attila Gáspár, Éva Széles, Harald Berndt
Dátum:2002
ISSN:1618-2642 1618-2650
Megjegyzések:A recently described thermospray flame furnace atomic absorption spectrometric (TS-FF-AAS) system has been modified in order to extend the applicability of the method for the determination of elemental traces in very small sample volumes (microliter or submicroliter). As an easily available, effective thermospray vaporizer, a fused silica capillary was used and the liquid sample was transported by 1 MPa (10 bar) gas pressure delivered by a standard gas cylinder. A 0.3 ?L sample volume can be analyzed with a higher power of detection than using 3 orders of magnitude larger sample volumes with conventional flame atomic absorption spectrometry. The relative standard deviations (N=12) for 0.3 ?L volumes and 5 ?g/mL Pb samples amount to 3.1% and 3.8% in signal height and signal area, respectively. The detection limit was found to be 69 ng/mL. Initial experiments with other elements (Cd, Hg, Tl, Zn) led to similar results.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Thermospray
FFAAS
Spectrometry
atomic absorption
microthermospray
Megjelenés:Analytical and Bioanalytical Chemistry. - 372 : 1 (2002), p. 136-140. -
További szerzők:Széles Éva (1979-) (vegyész) Berndt, Harald
Pályázati támogatás:FKFP 23/2001
Egyéb
Internet cím:Szerző által megadott URL
Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

3.

001-es BibID:BIBFORM010519
Első szerző:Gáspár Attila (vegyész, kémikus)
Cím:Application of external micro-spectrophotometric detection to improve sensitivity on microchips / Attila Gáspár, István Bácsi, Erika F. Garcia, Mihály Braun, Frank A. Gomez
Dátum:2009
ISSN:1618-2642
Megjegyzések:The goal of this work was to increase the sensitivity of a UV-Vis spectrophotometer by decreasing the background noise and lengthening the optical path. A microphotometer has been modified to precisely select very small parts of a microfluidic channel pattern of a chip and to measure light absorbance on a magnified area of the selected part of the channel. The viability of combining a projection microscope and a spectrophotometer for external absorbance measurements on disposable PDMS chips was studied. Besides the external direct detection above a microfluidic channel, the optical pathlength was lengthened by detecting in the region of the perpendicular exit port. Increasing the cross-sectional area of the zone of irradiation improved the signal-to-noise ratio and the limits of detection (LOD).
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Analytical and Bioanalytical Chemistry. - 395 : 2 (2009), p. 473-478. -
További szerzők:Bácsi István (1977-) (biológus) Garcia, Erika F. Braun Mihály (1966-) (vegyész, analitikus) Gomez, Frank A.
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

4.

001-es BibID:BIBFORM068812
035-os BibID:(WoS)000401408300008 (Scopus)85015170172
Első szerző:Kecskeméti Ádám (vegyész)
Cím:Development of an enzymatic reactor applying spontaneously adsorbed trypsin on the surface of a PDMS microfluidic device / Adam Kecskemeti, Jozsef Bako, Istvan Csarnovics, Eva Csosz, Attila Gaspar
Dátum:2017
ISSN:1618-2642 1618-2650
Megjegyzések:Herein, a microfluidic device (MD) containing immobilized trypsin for rapid and efficient proteolysis was described. Trypsin was immobilized via non-specific protein adsorption onto the hydrophobic poly(dimethylsiloxane) (PDMS) channel wall of the MD. Peptide mapping of bovine serumalbumin (BSA) samples was carried out to estimate the stability of trypsin adsorbed on PDMS surface. Peptide maps of BSA samples were obtained by capillary zone electrophoresis (CZE), the RSD% for migration times were under 1%. Several proteins (hemoglobin, myoglobin, lysozyme, and BSA) in a wide molecular size range (15?70 kDa) were digested efficiently with ?50 s contact time. The number of separated peaks correlated well with the expected number of peptides formed in the complete tryptic digestion of the proteins. Peptide mass fingerprinting of BSA and human serum was carried out.Trypsin retained its activity for 2 h; within this period, theMDcan be used for multiple digestions. The main properties of this device are simple channel pattern, simple immobilization procedure, regenerability, and disposability;all these features make this MD one of the simplest yet applicable enzymatic microreactors.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Immobilization
Trypsin
Digestion
Peptide mapping
Enzyme reactor
Microfluidic device
Megjelenés:Analytical and Bioanalytical Chemistry. - 409 : 14 (2017), p. 3573-3585. -
További szerzők:Bakó József (1981-) (vegyész) Csarnovics István (1986-) (fizikus) Csősz Éva (1977-) (biokémikus, molekuláris biológus) Gáspár Attila (1970-) (vegyész, kémikus)
Pályázati támogatás:OTKA-111932
OTKA
GINOP-2.3.2-15-2016-00008
GINOP
GINOP-2.3.3-15-2016-00004
GINOP
NTP- EFÖ-P-15-0003
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

5.

001-es BibID:BIBFORM098822
035-os BibID:(WoS)000683637100002 (Scopus)85112209771
Első szerző:Nagy Cynthia (1994-)
Cím:Study of the geometry of open channels in a layer-bed-type microfluidic immobilized enzyme reactor / Nagy Cynthia, Huszank Robert, Gaspar Attila
Dátum:2021
ISSN:1618-2642 1618-2650
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Analytical And Bioanalytical Chemistry. - 413 : 25 (2021), p. 6321-6332. -
További szerzők:Huszánk Róbert (vegyész kutató) Gáspár Attila (1970-) (vegyész, kémikus)
Pályázati támogatás:GINOP-2.3.2-15-2016-00008
GINOP
GINOP-2.3.3-15-2016-00004
GINOP
K127931
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1