Magyar
Toggle navigation
Tudóstér
Magyar
Tudóstér
Keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Egyszerű keresés
Összetett keresés
CCL keresés
Böngészés
Saját polc tartalma
(
0
)
Korábbi keresések
CCL parancs
CCL
Összesen 3 találat.
#/oldal:
12
36
60
120
Rövid
Hosszú
MARC
Részletezés:
Rendezés:
Szerző növekvő
Szerző csökkenő
Cím növekvő
Cím csökkenő
Dátum növekvő
Dátum csökkenő
1.
001-es BibID:
BIBFORM086134
035-os BibID:
(WoS)000454236100008 (Scopus)85056178968
Első szerző:
Aidala, C. A.
Cím:
Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes / C. A. Aidala, V. Bailey, S. Beckman, R. Belmont, C. Biggs, J. Blackburn, S. Boose, M. Chiu, M. Connors, E. Desmond, A. Franz, J. S. Haggerty, X. He, M. M. Higdon, J. Huang, K. Kauder, E. Kistenev, J. LaBounty, J. G. Lajoie, M. Lenz, W. Lenz, S. Li, V. R. Loggins, E. J. Mannel, T. Majoros, M. P. McCumber, J. L. Nagle, M. Phipps, C. Pinkenburg, S. Polizzo, C. Pontieri, M. L. Purschke, J. Putschke, M. Sarsour, T. Rinn, R. Ruggiero, A. Sen, A. M. Sickles, M. J. Skoby, J. Smiga, P. Sobel, P. W. Stankus, S. Stoll, A. Sukhanov, E. Thorsland, F. Toldo, R. S. Towell, B. Ujvari, S. Vazquez-Carson, C. L. Woody
Dátum:
2018
ISSN:
0018-9499
Megjegyzések:
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider will perform high-precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with the plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is 2.8%? 15.5%/?E and the energy resolution for hadrons in the combined EMCal plus HCal system is 13.5%?64.9%/?E. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
Tárgyszavak:
Természettudományok
Fizikai tudományok
idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:
IEEE Transactions On Nuclear Science. - 65 : 12 (2018), p. 2901-2919. -
További szerzők:
Bailey, Virginia
Beckman, S.
Belmont, R.
Biggs, C.
Blackburn, J.
Boose, S.
Chiu, M.
Connors, M.
Desmond, E.
Franz, A.
Haggerty, J. S.
He, Xiaochun
Higdon, M. M.
Huang, Jin
Kauder, Kolja
Kistenev, E.
LaBounty, J.
Lajoie, J. G.
Lenz, M.
Lenz, W.
Li, S.
Loggins, V. R.
Mannel, Eric J.
Majoros Tamás (1991-) (mérnök, informatikus)
McCumber, M. P.
Nagle, J. L.
Phipps, M.
Pinkenburg, Christopher
Polizzo, S.
Pontieri, C.
Purschke, M. L.
Putschke, J.
Sarsour, M.
Rinn, T.
Ruggiero, R.
Sen, A.
Sickles, A. M.
Skoby, M. J.
Smiga, J.
Sobel, P.
Stankus, P. W.
Stoll, S.
Sukhanov, A.
Thorsland, E.
Toldo, F.
Towell, R. S.
Ujvári Balázs (1977-) (fizikus)
Vazquez-Carson, S.
Woody, C. L.
Internet cím:
Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
2.
001-es BibID:
BIBFORM086133
Első szerző:
Bíró Barna
Cím:
A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers / B. Biro, G. David, A. Fenyvesi, J. S. Haggerty, J. Kierstead, E. J. Mannel, T. Majoros, J. Molnar, F. Nagy, S. Stoll, B. Ujvari, C. L. Woody
Dátum:
2019
ISSN:
0018-9499
Megjegyzések:
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of multipixel photon counters from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at the Brookhaven National Laboratory and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10 8 to 10 12 n/cm 2 . The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This paper was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.
Tárgyszavak:
Természettudományok
Fizikai tudományok
idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:
IEEE Transactions On Nuclear Science. - 66 : 7 (2019), p. 1833-1839. -
További szerzők:
Dávid Gábor (fizikus)
Fenyvesi András
Haggerty, J. S.
Kierstead, J.
Mannel, Eric J.
Majoros Tamás (1991-) (mérnök, informatikus)
Molnár József
Nagy Ferenc (1984-) (fizikus)
Stoll, S.
Ujvári Balázs (1977-) (fizikus)
Woody, C. L.
Internet cím:
Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
3.
001-es BibID:
BIBFORM015699
Első szerző:
Hegyesi Gyula (villamosmérnök)
Cím:
Ethernet Based Distributed Data Acquisition System for a Small Animal PET / Gy. Hegyesi, J. Imrek, G. Kalinka, J. Molnár, D. Novák, J. Végh, L. Balkay, M. Emri, S. A. Kis, G. Molnár, L. Trón, I. Valastyán, I. Bagaméry, T. Bükki, S. Rózsa, Zs. Szabó, A. Kerek
Dátum:
2006
ISSN:
0018-9499
Megjegyzések:
We report on the design of a small animal PET scanner being developed at our institutes. The existing setup is the first version of the miniPET machine consisting of four detector modules. Each detector module consists of an 8times8 LSO scintillator crystal block, a position sensitive photomultiplier, a digitizer including a digital signal processing board and an Ethernet interface board. There is no hardware coincidence detection implemented in the system and coincidence is determined based on a time stamp attached to every event by a digital CFD algorithm. The algorithm is implemented in the digital signal processing board and generates a time stamp with a coincidence resolution of less than 2 ns. The data acquisition system is based on Ethernet network and is highly scalable in size and performance
Tárgyszavak:
Műszaki tudományok
Villamosmérnöki tudományok
idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:
Ieee Transactions On Nuclear Science 53 : 4 (2006), p. 2112-2117. -
További szerzők:
Imrek József (1980-)
Kalinka Gábor
Molnár József (1954-) (villamosmérnök)
Novák Dezső Imre (1971-) (villamosmérnök)
Végh János (1953-) (fizikus)
Balkay László (1963-) (biofizikus)
Emri Miklós (1962-) (fizikus)
Kis Sándor Attila (1973-) (fizikus)
Molnár Gergely (1979-) (informatikus)
Trón Lajos (1941-) (biofizikus)
Valastyán Iván (1979-) (fizikus, informatikus)
Bagaméry István
Bükki Tamás
Rózsa Sándor (villamosmérnök)
Szabó Zsolt (1963-) (fizikus)
Kerék András (fizikus)
Internet cím:
Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
Rekordok letöltése
1
Corvina könyvtári katalógus v8.2.27
© 2023
Monguz kft.
Minden jog fenntartva.