CCL

Összesen 3 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM001568
Első szerző:Kis Sándor Attila (fizikus)
Cím:Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner / S. A. Kis, M. Emri, G. Opposits, T. Bükki, I. Valastyán, Gy. Hegyesi, J. Imrek, G. Kalinka, J. Molnár, D. Novák, J. Végh, A. Kerek, L. Trón, L. Balkay
Dátum:2007
Megjegyzések:In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
Tárgyszavak:Műszaki tudományok Orvostudományok Informatikai tudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Nuclear Instruments & Methods In Physics Research Section A-Accelerators Spectrometers Detectors And Associated Equipment 571 : 1-2 (2007), p. 449-452. -
További szerzők:Emri Miklós (1962-) (fizikus) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Bükki Tamás Valastyán Iván (1979-) (fizikus, informatikus) Hegyesi Gyula (1963-) (villamosmérnök) Imrek József (1980-) Kalinka Gábor Molnár József (1954-) (villamosmérnök) Novák Dezső Imre (1971-) (villamosmérnök) Végh János (1953-) (fizikus) Kerék András (fizikus) Trón Lajos (1941-) (biofizikus) Balkay László (1963-) (biofizikus)
Internet cím:elektronikus változat
elektronikus változat
DOI
Borító:

2.

001-es BibID:BIBFORM061303
Első szerző:Krizsán Áron Krisztián (fizikus)
Cím:A Promising Future : comparable Imaging Capability of MRI-Compatible Silicon Photomultiplier and Conventional Photosensor Preclinical PET Systems / Aron K. Krizsan, Imre Lajtos, Magnus Dahlbom, Freddie Daver, Miklos Emri, Sandor A. Kis, Gabor Opposits, Laszlo Pohubi, Norbert Potari, Gyula Hegyesi, Gabor Kalinka, Janos Gal, Jozsef Imrek, Ferenc Nagy, Ivan Valastyan, Beata Kiraly, Jozsef Molnar, Delfo Sanfilippo, Laszlo Balkay
Dátum:2015
ISSN:0161-5505
Megjegyzések:We recently completed construction of a small-animal PET system- the MiniPET-3-that uses state-of-the-art silicon photomultiplier (SiPM) photosensors, making possible dual-modality imaging with MRI. In this article, we compare the MiniPET-3 with the MiniPET-2, a system with the same crystal geometry but conventional photomultiplier tubes (PMTs). Methods: The standard measurements proposed by the National Electrical Manufacturers Association NU 4 protocols were performed on both systems. These measurements included spatial resolution, system sensitivity, energy resolution, counting rate performance, scatter fraction, spillover ratio for air and water, recovery coefficient, and image uniformity. The energy windows were set to 350-650 keV on the MiniPET-2 and 360-662 keV on the MiniPET-3. Results: Spatial resolution was approximately 17% better on average for the MiniPET-3 than the MiniPET-2. The systems performed similarly in terms of peak absolute sensitivity (~1.37%), spillover ratio for air (~0.15), spillover ratio for water (~0.25), and recovery coefficient (~0.33, 0.59, 0.81, 0.89, and 0.94). Uniformity was 5.59% for the MiniPET-2 and 6.49% for the MiniPET-3. Minor differences were found in scatter fraction. With the ratlike phantom, the peak noise-equivalent counting rate was 14 kcps on the MiniPET-2 but 24 kcps on the MiniPET-3. However, with the mouselike phantom, these values were 55 and 91 kcps, respectively. The optimal coincidence time window was 6 ns for the MiniPET-2 and 8 ns for the MiniPET-3. Conclusion: Images obtained with the SiPM-based MiniPET-3 small-animal PET system are similar in quality to those obtained with the conventional PMT-based MiniPET-2.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
MiniPET
small-animal PET scanner
performance evaluation
instrumentation
molecular imaging
Megjelenés:Journal Of Nuclear Medicine 56 : 12 (2015), p. 1948-1953. -
További szerzők:Lajtos Imre (1986-) (fizikus) Dahlbom, Magnus Daver, Freddie Emri Miklós (1962-) (fizikus) Kis Sándor Attila (1973-) (fizikus) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Pohubi László (1959-) (fizikus) Pótári Norbert (1980-) (vegyész) Hegyesi Gyula (1963-) (villamosmérnök) Kalinka Gábor Gál János Imrek József (1980-) Nagy Ferenc (1984-) (fizikus) Valastyán Iván (1979-) (fizikus, informatikus) Király Beáta (fizikus) Molnár József Sanfilippo, Delfo Balkay László (1963-) (biofizikus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM056510
Első szerző:Krizsán Áron Krisztián (fizikus)
Cím:Performance Comparison of SiPM and PMT Based Preclinical PET Systems with Same Detector Geometries (P004) / A. K. Krizsán, I. Lajtos, M. Emri, S. A. Kis, G. Opposits, G. Hegyesi, G. Kalinka, J. Gál, B. Király, J. Imrek, I. Valastyán, J. Molnár, D. Sanfilippo, M. Dahlbom, L. Balkay
Dátum:2014
ISSN:1619-7070
Tárgyszavak:Orvostudományok Klinikai orvostudományok konferenciacikk
Megjelenés:European Journal of Nuclear Medicine and Molecular Imaging 41 : S2 (2014), p. S360. -
További szerzők:Lajtos Imre (1986-) (fizikus) Emri Miklós (1962-) (fizikus) Kis Sándor Attila (1973-) (fizikus) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Hegyesi Gábor Kalinka Gábor Gál J. Király B. Imrek József (1980-) Valastyán Iván (1979-) (fizikus, informatikus) Molnár J. Sanfilippo, Delfo Dahlbom, Magnus Balkay László (1963-) (biofizikus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1