CCL

Összesen 1 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM004878
035-os BibID:(scopus)26444586247 (wos)000232299300007
Első szerző:Nagy Péter (biofizikus)
Cím:Novel calibration method for flow cytometric fluorescence resonance energy transfer measurements between visible fluorescent proteins / Nagy, P., Bene, L., Hyun, W. C., Vereb, G., Braun, M., Antz, C., Paysan, J., Damjanovich, S., Park, J. W., Szollosi, J.
Dátum:2005
ISSN:1552-4922
Megjegyzések:The combination of fluorescence resonance energy transfer (FRET) and flow cytometry offers a statistically firm approach to study protein associations. Fusing green fluorescent protein (GFP) to a studied protein usually does not disturb the normal function of a protein, but quantitation of FRET efficiency calculated between GFP derivatives poses a problem in flow cytometry. METHODS: We generated chimeras in which cyan fluorescent protein (CFP) was separated by amino acid linkers of different sizes from yellow fluorescent protein (YFP) and used them to calibrate the cell-by-cell flow cytometric FRET measurements carried out on two different dual-laser flow cytometers. Then, CFP-Kip1 was coexpressed in yeast cells with YFP and cyclin-dependent kinase-2 (Cdk2) and served as a positive control for FRET measurements, and CFP-Kip1 coexpressed with a random peptide fused to YFP was the negative control. RESULTS: We measured donor, direct, and sensitized acceptor fluorescence intensities and developed a novel way to calculate a factor (alpha) that characterized the fluorescence intensity of acceptor molecules relative to the same number of excited donor molecules, which is essential for quantifying FRET efficiency. This was achieved by calculating FRET efficiency in two different ways and minimizing the squared difference between the two results by changing alpha. Our method reliably detected the association of Cdk2 with its inhibitor, Kip1, whereas the nonspecific FRET efficiency between Cdk2 and a random peptide was negligible. We identified and sorted subpopulations of yeast cells showing interaction between the studied proteins. CONCLUSIONS: We have described a straightforward novel calibration method to accurately quantitate FRET efficiency between GFP derivatives in flow cytometry
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
analysis
Biophysics
Calibration
Cells
chemistry
Cyclin-Dependent Kinase 2
Cyclin-Dependent Kinase Inhibitor p27
Energy Transfer
Flow Cytometry
Fluorescence
Fluorescence Resonance Energy Transfer
Hungary
metabolism
methods
Protein Binding
Proteins
Research
Saccharomyces cerevisiae
Saccharomyces cerevisiae Proteins
Support
Megjelenés:Cytometry. Part A. - 67 : 2 (2005), p. 86-96. -
További szerzők:Bene László (1963-) (biofizikus) Hyun, William C. Vereb György (1965-) (biofizikus, orvos) Braun, Manuel Antz, Christof Paysan, Jacques Damjanovich Sándor (1936-2017) (biofizikus) Park, John W. Szöllősi János (1953-) (biofizikus)
Internet cím:elektronikus változat
DOI
Borító:
Rekordok letöltése1