CCL

Összesen 2 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM023396
Első szerző:Hallgas Balázs
Cím:Comparison of measured and calculated lipophilicity of substituted aurones and related compounds / B. Hallgas, T. Patonay, A. Kiss-Szikszai, Zs. Dobos, F. Hollósy, D. Erős, L. Őrfi, Gy. Kéri, M. Idei
Dátum:2004
Megjegyzések:A molecule library containing 55 aurone- and thioaurone-type structures has been designed and synthesised. Reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed to separate these compounds and to characterise their lipophilicity by experimental method (k'). The experimental lipophilicity data have been compared with the computer calculated lipophilicity parameters (CLOGPs) of the same molecules. In general, good correlations between the measured and calculated lipophilicities have been found with the exception of structure isomers and compounds capable for hydrogen bonding. The chromatographic method was suitable to separate the structure (ortho and para) isomers of aurone and thioaurones and was sensitive enough to differentiate their lipophilicities. Our findings suggest the usefulness of the chromatographic method in fast characterisation of the lipophilicity of structurally closely related molecules.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Lipophilicity
Aurones
Megjelenés:Journal of Chromatography B. Analytical Technologies in the Biomedical and Life Sciences. - 801 : 2 (2004), p. 229-235. -
További szerzők:Patonay Tamás (1951-2015) (vegyész) Kiss-Szikszai Attila (1975-) (vegyész) Dobos Zs. Hollósy F. Erős D. Őrfi László Kéri György Idei Miklós
Pályázati támogatás:37188, 32415
OTKA
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM004130
Első szerző:Huszár Mónika
Cím:Lipophilicity of Substituted Aurones and Related Compounds Measured on Immobilized Artificial Membrane (IAM) and Conventional C8 (MOS) Columns / Mónika Huszár, Balázs Hallgas, Miklós Idei, Attila Kiss-Szikszai, Anikó Horváth, Tamás Patonay
Dátum:2008
Megjegyzések:A high performance liquid chromatographic method utilizing an immobilized artificial membrane (IAM HPLC) column has been developed to separate the members of a library containing 38 aurone and thioaurone type structures and to characterise their lipophilicity. The experimental lipophilicity data (k'IAM) have been compared with the previously determined ones C8(MOS) column (k'MOS) and with their calculated lipophilicity parameters (CLOGP). In general, good correlations between the measured and calculated lipophilicities have been found both for the IAM and MOS column. The IAM column showed higher efficiency in separation of isomeric aurones or thioaurones than the MOS one and, consequently, it showed higher potential in differentiation of their lipophilicities. Our findings proved the usefulness of the HPLC method in fast characterisation of the lipophilicity of drug candidates closely related in structure.
Tárgyszavak:Természettudományok Kémiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Aurone
Immobilized Artificial membrane (IAM) column
Lipophilicity
Molecular library
Retention factor
Thioaurones
Megjelenés:Journal of Liquid Chromatography and Related Technologies. - 31 (2008), p. 3143-3158. -
További szerzők:Hallgas Balázs Idei Miklós Kiss-Szikszai Attila (1975-) (vegyész) Horváth Anikó Patonay Tamás (1951-2015) (vegyész)
Internet cím:DOI
elektronikus változat
Borító:
Rekordok letöltése1