CCL

Összesen 2 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM108128
035-os BibID:(Wos)000432849300001 (Scopus)85046669059
Első szerző:Arce, Pedro
Cím:The network of photodetectors and diode lasers of the CMS Link alignment system / Arce, P., Barcala, J.M., Calvo, E., Ferrando, A., Josa, M.I., Molinero, A., Navarrete, J., Oller, J.C., Brochero, J., Calderón, A., Fernández, M.G., Gómez, G., González-Sánchez, F.J., Martínez-Rivero, C., Matorras, F., Rodrigo, T., Ruiz-Árbol, P., Scodellaro, L., Sobrón, M., Vila, I., Virto, A.L., Fernández, J., Raics, P., Szabó, Zs., Trócsnyi, Z., Ujvári, B., Zilizi, Gy., Béni, N., Christian, G., Imrek, J., Molnar, J., Novak, D., Pálinkás, J., Székely, G., Szillási, Z., Bencze, G.L., Vestergombi, G., Benettoni, M., Gasparini, F., Montecassiano, F., Rampazzo, M., Zago, M., Benvenuti, A., Reithler, H., Jiang, C.
Dátum:2018
ISSN:0168-9002
Megjegyzések:The central feature of the CMS Link alignment system is a network of Amorphous Silicon Position Detectors distributed throughout the muon spectrometer that are connected by multiple laser lines. The data collected during the years from 2008 to 2015 is presented confirming an outstanding performance of the photo sensors during more than seven years of operation. Details of the photo sensor readout of the laser signals are presented. The mechanical motions of the CMS detector are monitored using these photosensors and good agreement with distance sensors is obtained.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
CMS
Alignment
Amorphous silicon photodetectors
Megjelenés:Nuclear Instruments & Methods In Physics Research Section A-Accelerators Spectrometers Detectors And Associated Equipment. - 896 (2018), p. 1-23. -
További szerzők:Barcala, José Miguel Calvo, E. Ferrando, Antonio Josa, M.I. Molinero, Antonio Navarrete, Javier Oller, Juan Carlos Brochero, J. Calderón, Alicia Fernández, M.G. Gómez, Gervasio González-Sánchez, Francisco Javier Martínez-Rivero, C. Matorras, Francisco Rodrigo, T. Ruiz-Árbol, Pablo Scodellaro, Luca Sobrón, Mar Vila, Ivan Virto, Amparo Lopez Fernández, Javier Raics Péter (1944-) (fizikus) Szabó Zsolt (1963-) (fizikus) Trócsányi Zoltán (1961-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Béni Noémi (1980-) (kísérleti fizikus) Christian, G. Imrek József (1980-) Molnár J. Novák D. Pálinkás József (1952-) (fizikus) Székely Gábor Szillási Zoltán (1971-) (fizikus) Bencze György L. (fizikus) Vesztergombi György (1943-2016) (fizikus) Benettoni, M. Gasparini, Fabrizio Montecassiano, Fabio Rampazzo, M. Zago, M. Benvenuti, Alberto Reithler, Hans Jiang, Cheng-Shi
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM094596
Első szerző:García-Moral, L. A.
Cím:Motions of CMS detector structures due to the magnetic field forces as observed by the Link alignment system during the test of the 4T magnet solenoid / L. A. García-Moral, G. Gómez, F. J. González-Sánchez, C. Martínez-Rivero, F. Matorras, T. Rodrigo, P. Martínez, L. Scodellaro, I. Vila, A. L. Virto, M. Sobrón, J. Alberdi, P. Arce, J. M. Barcala, E. Calvo, A. Ferrando, M. I. Josa, A. Molinero, J. Navarrete, J. C. Oller, C. Yuste, N. Béni, P. Raics, Zs. Szabó, Z. Trócsnyi, B. Ujvári, Gy. Zilizi, G. Christian, J. Imrek, J. Molnár, D. Novák, J. Pálinkás, G. Székely, Z. Szillási, G. L. Bencze, G. Vesztergombi, A. Calderón, M. Benettoni, F. Gasparini, F. Montecassiano, M. Rampazzo, M. Zago, A. Benvenuti
Dátum:2009
Megjegyzések:This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Alignment
CMS
Detectors
Megjelenés:Nuclear Instruments & Methods In Physics Research Section A : Accelerators Spectrometers Detectors And Associated Equipment. - 606 : 3 (2009), p. 344-361. -
További szerzők:Gómez, Gervasio González-Sánchez, Francisco Javier Martínez-Rivero, C. Matorras, Francisco Rodrigo, T. Martínez, P. Scodellaro, Luca Vila, Ivan Virto, Amparo Lopez Sobrón, Mar Alberdi, J. Arce, Pedro Barcala, José Miguel Calvo, E. Ferrando, Antonio Josa, M. I. Molinero, Antonio Navarrete, Javier Oller, Juan Carlos Yuste, C. Béni Noémi (1980-) (kísérleti fizikus) Raics Péter (1944-) (fizikus) Szabó Zsolt (1963-) (fizikus) Trócsányi Zoltán (1961-) (fizikus) Ujvári Balázs (1977-) (fizikus) Zilizi Gyula (1965-) (fizikus) Christian, G. Imrek József (1980-) Molnár J. Novák D. Pálinkás József (1952-) (fizikus) Székely G. Szillási Zoltán (1971-) (fizikus) Bencze György L. (fizikus) Vesztergombi György (1943-2016) (fizikus) Calderón, Alicia Benettoni, M. Gasparini, Fabrizio Montecassiano, Fabio Rampazzo, M. Zago, M. Benvenuti, Alberto
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1