CCL

Összesen 4 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM070273
Első szerző:De Greef, Yves
Cím:Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD : results of the PRECISION GOLD trial / De Greef Yves, Dekker Lukas, Boersma Lucas, Murray Stephen, Wieczorek Marcus, Spitzer Stefan G., Davidson Neil, Furniss Steve, Hocini Mélèze, Geller J. Christoph, Csanádi Zoltan, PRECISION GOLD investigators
Dátum:2016
ISSN:1099-5129
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Europace 18 : 5 (2016), p. 687-695. -
További szerzők:Dekker, Lukas Boersma, Lucas Murray, Stephen Wieczorek, Marcus Spitzer, Stefan G. Davidson, Neil Furniss, Steve Hocini, Mélèze Geller, J. Christoph Csanádi Zoltán (1960-) (kardiológus) PRECISION GOLD investigators
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM003756
Első szerző:Herczku Csaba (kardiológus)
Cím:Radiofrequency catheter ablation of premature ventricular complexes improved left ventricular function in a non-responder to cardiac resynchronization therapy / Herczku, C., Kun, C., Edes, I., Csanadi, Z.
Dátum:2007
Megjegyzések:Frequent premature ventricular complexes (PVCs) have been demonstrated to cause tachycardiomyopathy in some individuals with a structurally normal heart. We report a patient with severe congestive cardiomyopathy which did not respond to cardiac resynchronization therapy (CRT). Ambulatory monitoring and interrogation of the device memory revealed frequent monomorphic PVCs that were considered a potential cause of the failure of CRT. Radiofrequency ablation of the focus at the postero-inferior left ventricle eliminated the arrhythmia, with a resultant rapid improvement in the clinical status and echo parameters. As PVCs are often associated with severe heart failure, the presence of frequent extrasystoles may be an underrecognized cause of a non-response to resynchronization therapy
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Cardiomyopathy,Dilated
Catheter Ablation
Echocardiography
Electrocardiography
Heart Conduction System
Heart Failure
Heart Ventricles
Humans
Male
methods
Middle Aged
physiopathology
surgery
Ventricular Premature Complexes
Megjelenés:Europace. - 9 : 5 (2007), p. 285-288. -
További szerzők:Kun Csaba (1969-) (kardiológus) Édes István (1952-) (kardiológus) Csanádi Zoltán (1960-) (kardiológus)
Internet cím:elektronikus változat
DOI
Borító:

3.

001-es BibID:BIBFORM007428
Első szerző:Lemke, Bernd
Cím:Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability : the TULIP protocol / Lemke, B., Lawo, T., Zarse, M., Lubinski, A., Kreutzer, U., Mueller, J., Schuchert, A., Mitzenheim, S., Danilovic, D., Deneke, T., Csanadi, Z., The TULIP Study Group
Dátum:2008
ISSN:1532-2092 (Electronic)
Megjegyzések:We evaluated the feasibility of the TULIP (Threshold test using Upper Limit during ImPlantation) protocol, which was designed to provide a confirmed, low defibrillation energy value during implantable cardioverter defibrillator (ICD) implantation with only two induced ventricular fibrillation (VF) episodes. METHODS AND RESULTS: Ninety-eight patients (62 +/- 12 years, 86 male) from 13 clinical centres underwent an active can ICD implantation. A single coupling interval derived from electrocardiogram lead II during ventricular pacing was used for VF induction shocks at 13, 11, 9, and 6 J in a step-down manner until the upper limit of VF induction (ULVI) was determined. If ULVI >or=9 J, a defibrillation energy of ULVI + 4 J was tested. For ULVI <9 J, the defibrillation test energy was 9 J. In 79/98 patients (80.6%), two induced VF episodes were sufficient to obtain confirmed defibrillation energy of 11.1 +/- 3.3 J. The mean strength of the successful VF induction shock was 6.8 +/- 4.3 J, the coupling interval was 303 +/- 35 ms, and the number of delivered induction shocks until the first VF induction was 3.9 +/- 1.6. CONCLUSION: TULIP is a safe and simple device testing procedure allowing the determination of confirmed, low defibrillation energy in most patients with two VF episodes induced at a single coupling interval.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Algorithms
Defibrillators, Implantable
Equipment Design
Equipment Failure Analysis
Feasibility Studies
Female
Humans
Male
Middle Aged
Therapy, Computer-Assisted
Treatment Outcome
Ventricular Fibrillation
Megjelenés:Europace. - 10 : 8 (2008), p. 907-913. -
További szerzők:Lawo, Thomas Zarse, Markus Lubinski, Andrzej Kreutzer, Ulrich Mueller, Johannes Schuchert, Andreas Mitzenheim, Sabine Danilovic, Dejan Deneke, Thomas Csanádi Zoltán (1960-) (kardiológus) The TULIP Study Group
Internet cím:elektronikus változat
Borító:

4.

001-es BibID:BIBFORM035594
Első szerző:Merkely Béla (orvos)
Cím:Summary statement : EHRA summit 2010 with the participation of Central-Eastern European countries : 'ICD for Life' Initiative - fighting against sudden cardiac death in emerging economies / Béla Merkely, Josef Kautzner, Goran Milasinovic, Robert Hatala, Milos Taborsky, Andrzej Lubinski, George Andrei Dan, Endre Zima, Davor Milicic, Angelo Auricchio, A. John Camm, Christian Wolpert, Panos Vardas, EHRA Summit
Dátum:2011
ISSN:1099-5129
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
egyetemen (Magyarországon) készült közlemény
Megjelenés:Europace 13 : 8 (2011), p. 1209-1210. -
További szerzők:Kautzner, Josef Milasinovic, Goran Hatala, Robert Taborsky, Milos Lubinski, Andrzej Dan, George Andrei Zima Endre (1974-) (kardiológus) Milicic, Davor Auricchio, Angelo Camm, A. John Wolpert, Christian Vardas, Panos Csanádi Zoltán (1960-) (kardiológus) EHRA Summit
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1