CCL

Összesen 1 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM051790
035-os BibID:PMID:10214480
Első szerző:Vajda Zsolt
Cím:Transcranial Doppler-determined pulsatility index in the evaluation of endoscopic third ventriculostomy (preliminary data) / Z. Vajda, A. Büki, F. Vető, Z. Horváth, J. Sándor, T. Dóczi
Dátum:1999
ISSN:0001-6268
Megjegyzések:OBJECTIVE: Endoscopic 3rd ventriculostomy has become the method of choice in the management of occlusive hydrocephalus. The treatment is accompanied by significantly less peri-operative complications than the cerebrospinal fluid shunting procedures previously employed. Close surveillance of patients, however, is necessary to avoid the consequences of raised intracranial pressure that may develop in case of obstruction of the artificial outlet of the 3rd ventricle. The aim of this study was to confirm the value of transcranial Doppler-determined pulsatility index (PI) in the assessment of the patency of endoscopic 3rd ventriculostomy and to elucidate its usefulness in early postoperative recognition of increased intracranial pressure. METHODS: In twenty-two patients suffering from occlusive hydrocephalus, transcranial Doppler sonography (TCD) was performed before, immediately after, and five days after endoscopic fenestration of the floor of the 3rd ventricle. PI was defined with fast Fourier transformation. Mean PI values were determined in both middle cerebral arteries (MCA), over five cardiac cycles. RESULTS: In nineteen cases, PI values showed a significant decrease immediately as well as five days after the intervention as compared to the pre-operative values, and flow-sensitive MRI confirmed the patency of the fenestration in all cases. In one patient the operation failed to produce an effective diversion of cerebrospinal fluid as shown by flow-sensitive MRI, and the pulsatility index was unchanged. In two patients, a significant immediate postfenestration drop in PI was followed by a recurrence of PI to pre-operative levels without any clinical deterioration. CONCLUSIONS: Preliminary results suggest that the transcranial Doppler-determined pulsatility index is a useful non-invasive tool for the evaluation of the patency of the fenestration in the early follow-up of patients who underwent endoscopic third ventriculostomy.
Tárgyszavak:Orvostudományok Egészségtudományok idegen nyelvű folyóiratközlemény külföldi lapban
Endoscopic third ventriculostomy
occlusive hydrocephalus
pulsatility index
transcranial Doppler-sonography
Megjelenés:Acta Neurochirurgica. - 141 : 3 (1999), p. 247-250. -
További szerzők:Büki András (1990-) (általános orvos) Vető Ferenc Horváth Zsolt Sándor János (1966-) (orvos-epidemiológus) Dóczi Tamás
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1