CCL

Összesen 19 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM076777
035-os BibID:(WoS)000459881100037 (Scopus)85062412066 (PMID)30811546
Első szerző:Deák Eszter (klinikai laboratóriumi kutató)
Cím:Longitudinal changes in corneal cell and nerve fiber morphology 2 in young patients with type 1 diabetes with and without diabetic 3 retinopathy : a 2-year follow-up study / Eszter A. Deák, Eszter Szalai, Noémi Tóth, Rayaz A. Malik, András Berta, Adrienne Csutak
Dátum:2019
ISSN:0146-0404
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Investigative Ophthalmology & Visual Science. - 60 : 2 (2019), p. 830-837. -
További szerzők:Szalai Eszter (1984-) (orvos) Tóth Noémi (1992-) (orvos) Malik, Rayaz A. Berta András (1955-) (szemész, gyermekszemész) Csutak Adrienne (1971-) (szemész)
Pályázati támogatás:TÁMOP-4.2.2.A-11/1/KONV-2012-0045
TÁMOP
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

2.

001-es BibID:BIBFORM051660
Első szerző:Hassan, Ziad (szemész)
Cím:Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking / Ziad Hassan, László Módis, Eszter Szalai, András Berta, Gábor Németh
Dátum:2014
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Journal of Ophthalmology. - 7 : 2 (2014), p. 313-316. -
További szerzők:Módis László (1964-) (szemész szakorvos, kontaktológus) Szalai Eszter (1984-) (orvos) Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM047647
Első szerző:Hassan, Ziad (szemész)
Cím:Intraoperative and postoperative corneal thickness change after collagen crosslinking therapy / Ziad Hassan, Laszlo Modis, Eszter Szalai, Andras Berta, Gabor Nemeth
Dátum:2014
ISSN:1120-6721
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:European Journal of Ophthalmology. - 24 : 2 (2014), p. 179-185. -
További szerzők:Módis László (1964-) (szemész szakorvos, kontaktológus) Szalai Eszter (1984-) (orvos) Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

4.

001-es BibID:BIBFORM043390
Első szerző:Hassan, Ziad (szemész)
Cím:Assessment of corneal topography indices after collagen crosslinking for keratoconus / Ziad Hassan, Eszter Szalai, László Módis Jr., András Berta, Gábor Németh
Dátum:2013
ISSN:1120-6721
Megjegyzések:Objective: Riboflavin UVA (collagen crosslinking [CXL]) treatment for keratoconus is a method for stabilizing or improving corneal properties. Our aim was to evaluate changes in corneal topography indices after CXL. Methods: A total of 38 eyes of 25 patients (mean age 29.36 ± 9.7 years) were treated with CXL technique. The follow-up period was 36 months. Slit-lamp examination, visual acuity tests, and pachymetry measurements were performed; in order to obtain the following numerical data, corneal topography (TMS-4; Tomey) was used: simulated keratometry (K1, K2), CYL (cylinder value), SAI (surface asymmetry index), IAI (irregular astigmatism index), SRI (surface regulatory index), ACP (average corneal power), and CEI (corneal eccentricity index). Treatments were performed with In-Pro CCL-Lix (Germany) equipment. Results: The values of mean K1 (p = 0.82), cylinder (p = 0.73), SAI (p = 0.99), IAI (p = 0.82), SRI (p = 0.73), ACP (p = 0.73), K2 (p = 0.8), and CEI (p = 0.99) showed no significant changes at the end of the examination period. Uncorrected visual acuity remained unchanged (p = 0.32). However, best-corrected visual acuity changed from 0.21 ± 0.17 to 0.12 ± 0.11 in logMAR scale, but this deviation was not considered significant (p = 0.08). No change was observed in intraocular pressure (p = 0.79). Cornea remained clear and during follow-up period no corneal thinning was observed (p = 0.78). Conclusion: Our results suggest that corneal collagen CXL can be a successful treatment at certain stages of keratoconus, offering a way to stop progression in keratometric indices.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:European Journal of Ophthalmology. - 23 : 5 (2013), p. 635-640. -
További szerzők:Szalai Eszter (1984-) (orvos) Módis László (1964-) (szemész szakorvos, kontaktológus) Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

5.

001-es BibID:BIBFORM043673
Első szerző:Hassan, Ziad (szemész)
Cím:Collagen cross-linking in the treatment of pellucid marginal degeneration / Ziad Hassan, Gabor Nemeth, László Módis Jr., Eszter Szalai, András Berta
Dátum:2013
ISSN:1120-6721
Megjegyzések:Pellucid marginal degeneration (PMD) is an uncommon cause of inferior peripheral corneal thinning disorder, characterized by irregular astigmatism. We analyzed a case of bilateral PMD patient and treated one eye with corneal collagen cross-linking (CXL) therapy. Corneal topography was characteristic for PMD. Visual acuity, slitlamp examinations, tonometry, and corneal thickness were observed. Simulated keratometric and topographic index values were detected with corneal topography. Uncorrected, LogMAR visual acuity has improved from +0.8 to +0.55 during the 6 months and +0.3 during the 8 months follow-up after CXL. Pachymetry values and intraocular pressure showed no changes. Keratometric values and topografic indexes disclosed no progression of the disease. CXL may postpone or eliminate the need of corneal transplantation in cases with PMD.
Tárgyszavak:Orvostudományok Klinikai orvostudományok esettanulmány
Megjelenés:Indian Journal of Ophthalmology. - 62 : 3 (2013), p. 367-370. -
További szerzők:Németh Gábor (1975-) (szemész) Módis László (1964-) (szemész szakorvos, kontaktológus) Szalai Eszter (1984-) (orvos) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

6.

001-es BibID:BIBFORM065697
Első szerző:Kasza Márta
Cím:Plasma E-selectin levels can play a role in the development of diabetic retinopathy / Márta Kasza, J. Meleg, J. Vardai, B. Nagy, E. Szalai, J. Damjanovich, A. Csutak, B. Ujhelyi, V. Nagy
Dátum:2017
ISSN:0721-832X
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Graefes Archive For Clinical And Experimental Ophthalmology 255 : 1 (2017), p. 25-30. -
További szerzők:Meleg Judit Várdai Julianna Nagy Béla Jr. (1980-) (labordiagnosztikai szakorvos) Szalai Eszter (1984-) (orvos) Damjanovich Judit (1963-) (szemész) Csutak Adrienne (1971-) (szemész) Ujhelyi Bernadett (1981-) (szemész) Nagy Valéria (1962-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

7.

001-es BibID:BIBFORM071327
Első szerző:Liao, Albert
Cím:Radiologic and Histopathologic Correlation of Different Growth Patterns of Metastatic Uveal Melanoma to the Liver / Albert Liao, Pardeep Mittal, David H. Lawson, Jenny J. Yang, Eszter Szalai, Hans E. Grossniklaus
Dátum:2018
ISSN:0161-6420
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Ophthalmology. - 125 : 4 (2018), p. 597-605. -
További szerzők:Mittal, Pardeep Lawson, David H. Yang, Jenny J. Szalai Eszter (1984-) (orvos) Grossniklaus, Hans E.
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

8.

001-es BibID:BIBFORM072967
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Scanning-slit topography in patients with keratoconus / Módis L. Jr., Németh G., Szalai E., Flaskó Z., Seitz B.
Dátum:2017
ISSN:2222-3959 2227-4898
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Journal Of Ophthalmology 10 : 11 (2017), p. 1686-1692. -
További szerzők:Németh Gábor (1975-) (szemész) Szalai Eszter (1984-) (orvos) Flaskó Zsuzsanna Seitz, Berthold
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

9.

001-es BibID:BIBFORM062777
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device / László Módis, Ziad Hassan, Eszter Szalai, Zsuzsanna Flaskó, András Berta, Gábor Németh
Dátum:2016
ISSN:2222-3959 2227-4898
Megjegyzések:To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83?20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43?21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41?40.17mo (range: 11-128mo) after the keratoplasty and after 7.64?2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. ? 2016, International Journal of Ophthalmology (c/o Editorial Office). All rights reserved.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Corneal visualization Scheimpflug technology
Ocular biomechanics
Penetrating keratoplasty
Megjelenés:International Journal Of Ophthalmology 9 : 2 (2016), p. 235-238. -
További szerzők:Ziad, Hassan Szalai Eszter (1984-) (orvos) Flaskó Zsuzsanna Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

10.

001-es BibID:BIBFORM020312
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Dry eye diagnosis and management / Módis László, Szalai Eszter
Dátum:2011
ISSN:1746-9899
Megjegyzések:Dry eye disease is a very common multifactorial disease of the lacrimal functional unit that results in tear film instability, hyperosmolarity, chronic irritation and inflammation of the ocular surface. Diagnostic tools have been developing rapidly, however, both classic dry eye tests (Schirmer I test, fluorescein staining of the surface epithelium and tear film break-up time) and noninvasive imaging techniques are essential for an exact diagnosis. The management of dry eye syndrome can be either conservative or invasive based on the severity of the disease. The basic aim of treatment is to improve quality of life and reduce subjective complaints and objective ocular surface alterations in dry eye patients. The first line of treatment is tear substitution with artificial tear drops, gels and ointments. In moderate cases preservative-free tear supplementation, topical anti-inflammatory therapy and retinol treatment is recommended. Temporary or permanent punctal plug occlusion, therapeutic contact lenses or moisture chamber use constitute other options. In severe cases the application of topical autologous serum, systemic anti-inflammatory therapy, androgen substitution, secretagogues and surgical intervention can be effective. In the future, noninvasive diagnostic tools and instruments such as screening methods are likely to be developed. In addition, causal therapy of the dry eye will play a greater role, including cyclosporine therapy, secretion stimulation, growth factor-containing artificial tears, as well as secratogogues, immunomodulants and androgenic complexes for severe forms of the disease.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Expert Review of Ophthalmology. - 6 : 1 (2011), p. 67-79. -
További szerzők:Szalai Eszter (1984-) (orvos)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

11.

001-es BibID:BIBFORM020309
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Corneal transplantation in Hungary (1946-2009) / Módis L. Jr., Szalai E., Facskó A., Fodor M., Komár T., Berta A.
Dátum:2011
ISSN:1442-6404
Megjegyzések:To identify changing trends in indications for corneal transplantation in Debrecen, Hungary over the past 64 years. DESIGN: Retrospective study, at the Department of Ophthalmology, University of Debrecen, Hungary. PARTICIPANTS: Four thousand seven hundred and seventy-eight patients who underwent keratoplasty. METHODS: The analysis was based on medical charts, surgical descriptions and eye bank records. MAIN OUTCOME MEASURES: Keratoplasty indications between January 1946 and December 2009. For an easier overview, the 64-year interval was divided into seven time periods (1946-1955, I; 1956-1965, II; 1966-1975, III; 1976-1985, IV; 1986-1995, V; 1996-2005, VI; 2006-2009, VII). RESULTS: Over the 64 years, clinical indications for keratoplasty were corneal scarring (24.9%), regraft (18.6%), keratoconus (18.6%), pseudophakic/aphakic corneal oedema (12%), stromal corneal dystrophies (6%), non-infectious keratitis (4.7%), chemical injuries (3.3%), corneal degenerations (3%), mechanical trauma (1.7%), infectious keratitis (1.4%), endothelial corneal dystrophies (1.3%) and others (4.5%). During periods I-IV, corneal scarring was the most common indication for corneal transplantation. In period V, corneal ectasia became the leading clinical indication. Regraft was the most frequent indication in period VI. In the most recent years, an emerging tendency in pseudophakic/aphakic corneal oedema as the indication for keratoplasty was observed. CONCLUSIONS: In Hungary, the number of grafts has increased greatly in the past 64 years, the transplantation rates are similar to those of industrial countries. Indications for corneal transplantation have changed considerably over the last half decade from corneal scarring to corneal ectasia, regraft and pseudophakic/aphakic corneal oedema.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Clinical And Experimental Ophthalmology. - 39 : 6 (2011), p. 520-525. -
További szerzők:Szalai Eszter (1984-) (orvos) Facskó Andrea (1953-) (szemész) Fodor Mariann (1975-) (szemész) Komár Timea (1975-) (szemész) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

12.

001-es BibID:BIBFORM013624
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Evaluation of a recently developed noncontact specular microscope in comparison with conventional pachymetry devices / L. Módis Jr., E. Szalai, G. Németh, A. Berta
Dátum:2010
ISSN:1120-6721
Megjegyzések:PURPOSE: The study was conducted to assess the central corneal thickness (CCT) of the healthy cornea with a recently developed noncontact specular microscope (EM-3000; Tomey) and compare the results with those measured with a contact specular microscope and an ultrasound pachymeter. Agreement between measurements taken by 2 investigators was also studied. METHODS: The right eyes of 41 healthy individuals who had negative history of contact lens wear, ophthalmic disease, or ocular surgery were examined. The CCT was determined sequentially with a noncontact specular microscope, a contact specular microscope (EM-1000; Tomey), and an ultrasound pachymeter (AL-2000; Tomey). Each evaluation with the specular microscopes was performed by 2 independent operators. RESULTS: A significant difference was detected in pachymetry measurements among the 3 instruments (p=0.01; analysis of variance). The mean CCT values were lower measured with the ultrasound pachymeter (537+/-30 microm) than the contact endothelial microscope (543+/-37 microm, p=0.17, Student t-test) and the noncontact microscope (549+/-33 microm, p<0.0001) (operator 1). There was no statistically significant difference in CCT measurements between the 2 endothelial microscopes (p=0.19). We found significant correlations (p<0.0001) in thickness measurements between each pair of instruments (r=0.91, noncontact microscopy and ultrasound pachymetry; r=0.74, noncontact and contact microscopy; r=0.72, contact microscopy and ultrasound pachymetry; Spearman rank correlation). CONCLUSIONS: The strong correlations among the 3 pachymetry devices suggest that the tested instruments provide reliable measurements; however, they cannot be used interchangeably.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:European Journal of Ophthalmology. - 20 : 5 (2010), p. 831-838. -
További szerzők:Szalai Eszter (1984-) (orvos) Németh Gábor (1975-) (szemész) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1 2