1.
001-es BibID:
BIBFORM076524
Első szerző:
Reusz György
Cím:
Safety of ultrasound-guided central venous access in critically ill patients with uncorrected coagulopathy / G. Reusz, C. Langer, G. Egervári, P. Sárkány, A. Csomós
Dátum:
2013
ISSN:
1364-8535 1466-609X
Megjegyzések:
Coagulopathy in patients undergoing CVC insertion is common. We observed uncomplicated CVC placement in all 41 patients with severe uncorrected coagulopathy and in a further 76 patients with coagulopathy of moderate severity. When combined with other studies, our data suggest that ultrasound-guided CVC placement without routine correction of coagulation abnormalities may be safe in the ICU.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idézhető absztrakt
Megjelenés:
Critical Care. - 17 : 2 (2013), p. 65. -
További szerzők:
Langer Csilla
Egervári G.
Sárkány Péter (1966-) (aneszteziológus)
Csomós Ákos (1962-) (aneszteziológus)
Internet cím:
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
2.
001-es BibID:
BIBFORM076493
Első szerző:
Reusz György
Cím:
Needle-related ultrasound artifacts and their importance in anaesthetic practice / G. Reusz, P. Sarkany, J. Gal, A. Csomos
Dátum:
2014
Megjegyzések:
Real-time ultrasound guidance forany intervention relies on visualization of needle advancement towards a target. Unfortunately, correct identification of the needle tip is not straightforward, as artifacts always distort the image. The ultrasonic appearance of the needle is often degraded by reverberation, comet tail, side-lobe, beam-width, or bayonet artifacts, which can easily confuse an unprepared operator. Furthermore, the typical needle image, that is, a dot or a straight line (out-of-plane and in-plane approaches, respectively), is also a result of artifacts that hide the real dimensions of the needle. Knowledge and correct interpretation of these artifacts is important for safe practice and is paramount to success when precise needle manipulation is mandatory, for example, when the target is small. In this review, authors discuss the most important needle-related artifacts and provide a physical explanation focusing on implications for everyday practice. Recent advances that allow increased needle visualization and reduction of artifacts are also discussed.
Tárgyszavak:
Orvostudományok
Klinikai orvostudományok
idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:
British Journal of Anaesthesia. - 112 : 5 (2014), p. 794-802. -
További szerzők:
Sárkány Péter (1966-) (aneszteziológus)
Gál J.
Csomos A.
Internet cím:
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Saját polcon:
Rekordok letöltése
1