CCL

Összesen 3 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM071864
Első szerző:Green, R. W.
Cím:Inter- and intrarater reproducibility in detecting deep myometrial invasion and cervical stromal invasion using 2D-TVU and 3D-VCI / Green R. W., Valentin L., Alcazar J., Van den Bosch T., Chiappa V., Erdodi B., Franchi D., Fruhauf P., Fruscio R., Guerriero S., Graupera B., Jakab A., Di Legge A., Ludovisi M., Mascilini F., Pascual M., Epstein E.
Dátum:2017
Tárgyszavak:Orvostudományok Klinikai orvostudományok idézhető absztrakt
ultrasound
3D
gynecology
endometrial cancer
Megjelenés:International Society of Ultrasound in Obstetrics and Gynecology 50 : Suppl. 1. (2017), p. 197. -
További szerzők:Valentin, Lil Alcazar, Juan Luis Bosch, Thierry van den Chiappa, Valentina Erdődi Balázs (1984-) (szülész-nőgyógyász szakorvosjelölt) Franchi, Dorella Fruhauf, P. Fruscio, Robert Guerriero, Stefano Graupera, B. Jakab Attila (1964-) (szülész-nőgyógyász, endokrinológus) Di Legge, Alessia Ludovisi, Manuela Mascilini, Floriana Pascual, M. Angela Epstein, Elisabeth
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM071863
Első szerző:Green, R. W.
Cím:2D-TVU is more accurate modality than 3D-VCI in staging endometrial cancer / Green R. W., Valentin L., Alcazar J., Van den Bosch T., Chiappa V., Erdodi B., Franchi D., Fruhauf P., Fruscio R., Guerriero S., Graupera B., Jakab A., Di Legge A., Ludovisi M., Mascilini F., Pascual M., Epstein E.
Dátum:2017
Tárgyszavak:Orvostudományok Klinikai orvostudományok idézhető absztrakt
ultrasound
3D
gynecology
endometrial cancer
Megjelenés:International Society of Ultrasound in Obstetrics and Gynecology 50 : Suppl. 1. (2017), p. 36. -
További szerzők:Valentin, Lil Alcazar, Juan Luis Bosch, Thierry van den Chiappa, Valentina Erdődi Balázs (1984-) (szülész-nőgyógyász szakorvosjelölt) Franchi, Dorella Fruhauf, P. Fruscio, Robert Guerriero, Stefano Graupera, B. Jakab Attila (1964-) (szülész-nőgyógyász, endokrinológus) Di Legge, Alessia Ludovisi, Manuela Mascilini, Floriana Pascual, M. Angela Epstein, Elisabeth
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM077450
035-os BibID:(WoS)000444528400008 (Scopus)85049904747
Első szerző:Green, Rasmus W.
Cím:Endometrial cancer off-line staging using two-dimensional transvaginal ultrasound and three-dimensional volume contrast imaging : intermethod agreement, interrater reliability and diagnostic accuracy / Rasmus W. Green, Lil Valentin, Juan Luis Alcazar, Valentina Chiappa, Balazs Erdodi, Dorella Franchi, Filip Frühauf, Robert Fruscio, Stefano Guerriero, Betlem Graupera, Attila Jakab, Alessia di Legge, Manuela Ludovisi, Floriana Mascilini, M. Angela Pascual, Thierry van den Bosch, Elisabeth Epstein
Dátum:2018
ISSN:0090-8258
Megjegyzések:Objectives. The aim is to estimate agreement between two-dimensional transvaginal ultrasound (2D-TVS) and three-dimensional volume contrast imaging (3D-VCI) in diagnosing deep myometrial invasion (MI) and cer- vical stromal involvement (CSI) of endometrial cancer and to compare the two methods regarding inter-rater re- liability and diagnostic accuracy. Methods. Fifteen ultrasound experts assessed off-line de-identified 3D-VCI volumes and 2D-TVU video clips from 58 patients with biopsy-confirmed endometrial cancer regarding the presence of deep (?50%) MI and CSI. Video clips and 3D volumes were assessed independently. Interrater reliability was measured using kappa statistics. Histological diagnosis after hysterectomy served as gold standard. Accuracy measurements were corre- lated to rater experience using Spearman's rank correlation coefficient (?). Results. Agreement between 2D-TVU and 3D-VCI for diagnosing MI was median 76% (range 64?93%) and for CSI median 88% (range 79?97%). Interrater reliability was better for 2D-TVU than for 3D-VCI (Fleiss' kappa 0.41 vs. 0.31 for MI and 0.55 vs. 0.45 for CSI). Median accuracy for diagnosing deep MI was 76% (range 59?84%) with 2D-TVU and 69% (range 52?83%) for 3D-VCI; the corresponding figures for CSI were 88% (range 81?93%) and 86% (range 72?95%). Accuracy was significantly correlated to how many cases the raters assessed annually. Conclusions. Off-line assessment of MI and CSI in women with endometrial cancer using 3D-VCI has lower interrater reliability and lower accuracy than 2D-TVU video clip assessment. Since accuracy was cor- related to the number of cases assessed annually it is advised to centralize these examinations to high-vol- ume centres.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
endometrial cancer
ultrasound
diagnostic accuracy
Megjelenés:Gynecologic Oncology. - 150 : 3 (2018), p. 438-445. -
További szerzők:Valentin, Lil Alcazar, Juan Luis Chiappa, Valentina Erdődi Balázs (1984-) (szülész-nőgyógyász szakorvosjelölt) Franchi, Dorella Frühauf, Filip Fruscio, Robert Guerriero, Stefano Graupera, Betlem Jakab Attila (1964-) (szülész-nőgyógyász, endokrinológus) Di Legge, Alessia Ludovisi, Manuela Mascilini, Floriana Pascual, M. Angela Bosch, Thierry van den Epstein, Elisabeth
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1