CCL

Összesen 3 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM068009
Első szerző:Kiss Alexandra (általános orvos)
Cím:Phased RF Ablation : results and Concerns / Alexandra Kiss, Gábor Sándorfi, Edina Nagy-Baló, Mihran Martirosyan, Zoltan Csanadi
Dátum:2015
Megjegyzések:AbstractTreatment of atrial fibrillation (AF) with catheter ablation has proven to be a safe and effective treatment modality which is offered to an increasing number of patients in many centers. Pulmonary vein isolation (PVI) is an established cornerstone of AF ablation strategies. Athough the isolation of the pulmonary veins (PVs) with irrigated focal radiofrequency (RF) catheters using a point-by-point method is considered as the gold standard, it can be challenging to create contiguous lesions, time consuming, and require advanced three dimensional (3D) mapping and navigational systems. The phased RF ablation system was designed to address many of these challenges associated with conventional focal RF ablation. In this review, we describe the main features of phased RF ablation and summarize the data available on clinical outcome with this technology.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
atrial fibrillation
Megjelenés:Journal of Atrial Fibrillation. - 8 : 1 (2015), p. 45-53. -
További szerzők:Sándorfi Gábor (1976-) (belgyógyász, kardiológus) Nagy-Baló Edina (1985-) (kardiológus) Martirosyan, Mihran (1984-) (orvos, kardiológus) Csanádi Zoltán (1960-) (kardiológus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM057050
Első szerző:Martirosyan, Mihran (orvos, kardiológus)
Cím:Learning curve in circular multipolar phased radiofrequency ablation of atrial fibrillation / Mihran Martirosyan, Alexandra Kiss, Edina Nagy-Baló, Gábor Sándorfi, Diana Tint, István Édes, Zoltán Csanádi
Dátum:2015
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Cardiology Journal 22 : 3 (2015), p. 260-266. -
További szerzők:Kiss Alexandra (1987-) (általános orvos) Nagy-Baló Edina (1985-) (kardiológus) Sándorfi Gábor (1976-) (belgyógyász, kardiológus) Tint, Diana Édes István (1952-) (kardiológus) Csanádi Zoltán (1960-) (kardiológus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM068008
Első szerző:Nagy-Baló Edina (kardiológus)
Cím:Cerebral micro-embolization during pulmonary vein isolation : relation to post-ablation silent cerebral ischemia / Edina Nagy-Baló, Mihran Martirosyan, Gábor Sándorfi, Orsolya Hajas, Levente Lánczi, Ervin Berényi, Lilla Ladányi, Alexandra Kiss, István Édes, Zoltán Csanádi
Dátum:2017
Megjegyzések:AbstractBackground: High incidences of silent cerebral ischemia (SCI) have been revealed bydiffusion-weighted magnetic resonance imaging (DW MRI) after pulmonary vein isolation(PVI) for atrial fibrillation. A high number of mostly gaseous micro-embolic signals (MESs)was detected by transcranial Doppler (TCD) during PVI. In this investigation the possiblerelationship between MESs detected intraoperatively by TCD and new SCI on DW MRI postablationis reported.Methods: 27 consecutive atrial fibrillation patients (6 female, age median: 64 interquartilerange: 13.23) undergoing PVI with the pulmonary vein ablation catheter (PVAC), pre- andpost-ablation DW MRI and intraoperative MES detection by TCD were included in the study.Procedures were performed on a therapeutic international normalized ratio (2?3) and with atarget activated clotting time ? 350 s in all patients. DW MRI scans performed pre- and postablationrevealed new SCI in 6 out of 27 (22%) patients.Results: The median (interquartile range) MES count recorded during the whole procedurewas 1642 (912) in patients with and 1019 (529) in those without SCI (p = 0.129). The numberof MESs recorded during PV angiography was significantly higher in patients as compared tothose without a new lesion on the post-ablation DW MRI: 257 (249) vs. 110 (71), respectively(p = 0.0009). On multivariate logistic regression, the total MES count was predictive of SCIin patients older than 68 years.Conclusions: Micro-embolus generation detected by TCD during PV angiographysignificantly correlates with new SCI on DW MRI post-ablation.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
silent cerebral ischemia
diffusion-weighted magnetic resonance imaging
transcranial Doppler
microembolic signals
Megjelenés:Cardiology Journal 24 : 3 (2017), p. 234-241. -
További szerzők:Martirosyan, Mihran (1984-) (orvos, kardiológus) Sándorfi Gábor (1976-) (belgyógyász, kardiológus) Hajas Orsolya (1987-) Lánczi Levente (1990-) (általános orvos) Berényi Ervin (1964-) (radiológus) Ladányi Lilla Kiss Alexandra (1987-) (általános orvos) Édes István (1952-) (kardiológus) Csanádi Zoltán (1960-) (kardiológus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1