CCL

Összesen 2 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM060954
Első szerző:Janovics Róbert (környezetkutató)
Cím:Advances in radiocarbon measurement of water samples / Janovics R., Molnár M., Svĕtlík I., Major I., Wacker L.
Dátum:2011
ISSN:1789-6088
Megjegyzések:In this paper we present two very different and novel methods for 14C measurement of water samples. The first method uses direct absorption into a scintillation cocktail and a following liquid scintillation measurement. Typical sample size is 20-40 litre of water and overall uncertainty is +-2% for modern samples. It is a very cost-effective and easy to use method based on a novel and simple static absorption process for the CO2 extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using gas ion source. With a MICADAS type AMS system we demonstrated that you can routinely measure the 14C content of 1 ml of water sample with better than 1% precision (for a modern sample). This direct 14C AMS measurement of water takes less than 20 minutes including sample preparation.
Tárgyszavak:Természettudományok Fizikai tudományok idegen nyelvű folyóiratközlemény hazai lapban
Megjelenés:Acta Physica Debrecina. - 45 : 58 (2011), p. 58-68. -
További szerzők:Molnár Mihály (1974-) (fizikus) Svĕtlík, Ivo Major István (1985-) (környezetkutató) Wacker, Lucas (1956-) (Fizikus)
Internet cím:Szerző által megadott URL
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM060955
Első szerző:Janovics Róbert (környezetkutató)
Cím:Advances in radiocarbon measurement of water samples / R. Janovics, M. Molnár, I. Svĕtlík, I. Major, L. Wacker
Dátum:2013
Megjegyzések:In this paper two very different and novel methods for the 14C measurement of watersamples are presented. The first method uses direct absorption into a scintillation cocktailand a following liquid scintillation measurement. Typical sample size is 20-40 L and overalluncertainty is +-2% for modern samples. It is a very cost effective and easy to use methodbased on a novel and simple static absorption process for the CO2 extracted from groundwater.The other very sensitive method is based on accelerator mass spectrometry (AMS) using agas ion source. With a MICADAS type AMS system we demonstrated that you can routinelymeasure the 14C content of 1 mL of water sample with better than 1% precision (for a modernsample). This direct 14C AMS measurement of water takes less than 20 minutes including samplepreparation.
ISBN:978 92 0 135610 9
Tárgyszavak:Természettudományok Fizikai tudományok előadáskivonat
Megjelenés:Isotopes in Hydrology, Marine Ecosystems and Climate Change Studies Proceedings of the International Symposium held in Monaco, 27 March-1 April 2011. - 2. vol., p. 369-376. -
További szerzők:Molnár Mihály (1974-) (fizikus) Svĕtlík, Ivo Major István (1985-) (környezetkutató) Wacker, Lucas (1956-) (Fizikus)
Internet cím:Szerző által megadott URL
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1