CCL

Összesen 7 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM066065
Első szerző:Balogh Zsuzsa (orvos)
Cím:Analysis of optic disc damage by optical coherence tomography in terms of therapy in non-arteritic anterior ischemic optic neuropathy / Zsuzsa Balogh, Márta Kasza, Julianna Várdai, Izabella Reznek, Judit Damjanovich, Adrienne Csutak, András Berta, Valéria Nagy
Dátum:2016
ISSN:2222-3959 2227-4898
Megjegyzések:This study aimed to assess the relationship between the rate of nerve fiber loss in non-arteritic anterior ischemic optic neuropathy (NAION) and time delay before therapy. Total 24 patients received the same treatment within or after 2wk (early and late groups). There were significantly lower level of destruction of nerve fibers (P=0.0014) and significantly better visual field sensitivity (P=0.039) in early group. The results indicate that therapy should be started within 2wk. The degree of ischemic damage due to NAION correlates well with retinal nerve fiber layer thickness and the ischemia-induced decrease in visual field sensitivity.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
non-arteritic anterior ischemic optic neuropathy
optical coherence tomography
perimetry
retinal nerve fiber layer
Megjelenés:International Journal Of Ophthalmology 9 : 9 (2016), p. 1352-1354. -
További szerzők:Kasza Márta Várdai Julianna Reznek Izabella Damjanovich Judit (1963-) (szemész) Csutak Adrienne (1971-) (szemész) Berta András (1955-) (szemész, gyermekszemész) Nagy Valéria (1962-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM040774
Első szerző:Berta András (szemész, gyermekszemész)
Cím:Tear plasminogen activators - indicators of epithelial cell destruction. The effect of scraping, n-heptanol debridement, and alkali burn of the cornea on the plasminogen activator activity of rabbit tears / Berta, A., Holly, F. J., Tozser, J., Holly, T. F.
Dátum:1991
Megjegyzések:Plasminogen activator (uPA) activities were determined in the tears of rabbits following mechanical (scraping) or chemical (n-heptanol) debridement and alkali burn of the central part of the corneal epithelium. All three types of injury enhanced the plasminogen activator activities in the tears. The increase in uPA activity was highest in alkali burn, lowest for n-heptanol debridement. Scraping yielded an intermediate increase in uPA activity. The maximum value in activator activity was reached at 5 hours for mechanical injury and at 24 hours for chemical injuries. uPA activity values returned to the normal range by the time of re-epithelialization for mechanical scraping and 1-3 days following re-epithelialization for heptanol debridement and alkali burn. A trend was observed between uPA activity level and the size of the wound but the correlation was not pronounced (R = 0.538).
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Ophthalmology. - 15 : 6 (1991), p. 363-369. -
További szerzők:Holly, Frank J. Tőzsér József (1959-) (molekuláris biológus, biokémikus, vegyész) Holly, T. F.
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM051660
Első szerző:Hassan, Ziad (szemész)
Cím:Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking / Ziad Hassan, László Módis, Eszter Szalai, András Berta, Gábor Németh
Dátum:2014
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Journal of Ophthalmology. - 7 : 2 (2014), p. 313-316. -
További szerzők:Módis László (1964-) (szemész szakorvos, kontaktológus) Szalai Eszter (1984-) (orvos) Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

4.

001-es BibID:BIBFORM069177
Első szerző:Kriszt Ágnes (Orvos)
Cím:Presence of Fleischer ring and prominent corneal nerves in keratoconus relatives and normal controls / Kriszt Ágnes, Losonczy Gergely, Berta András, Takács Lili
Dátum:2015
ISSN:2222-3959 2227-4898
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Journal Of Ophthalmology 8 : 5 (2015), p. 922-927. -
További szerzők:Losonczy Gergely (1977-) (szemész) Berta András (1955-) (szemész, gyermekszemész) Takács Lili (1969-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

5.

001-es BibID:BIBFORM062777
Első szerző:Módis László (szemész szakorvos, kontaktológus)
Cím:Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device / László Módis, Ziad Hassan, Eszter Szalai, Zsuzsanna Flaskó, András Berta, Gábor Németh
Dátum:2016
ISSN:2222-3959 2227-4898
Megjegyzések:To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83?20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43?21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41?40.17mo (range: 11-128mo) after the keratoplasty and after 7.64?2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. ? 2016, International Journal of Ophthalmology (c/o Editorial Office). All rights reserved.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Corneal visualization Scheimpflug technology
Ocular biomechanics
Penetrating keratoplasty
Megjelenés:International Journal Of Ophthalmology 9 : 2 (2016), p. 235-238. -
További szerzők:Ziad, Hassan Szalai Eszter (1984-) (orvos) Flaskó Zsuzsanna Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

6.

001-es BibID:BIBFORM060017
Első szerző:Steiber Zita (orvos, szemész)
Cím:Plasminogen activator inhibitor type 2 in human tears and blood during pregnancy / Steiber Z., Tozser J., Silver D.M., Jakab A., Németh G., Berta A., Csutak A.
Dátum:2015
Megjegyzések:Purpose: During pregnancy, systemic blood levels of plasminogen activator inhibitors (PAIs), estradiol (E2) and progesterone (P4) are expected to rise with gestational age. This work examines whether a corresponding rise in PAIs occurs in tears. Methods: Tear and blood samples were collected opportunistically from women during pregnancy: PAI-2 and PAI-1 levels were measured using enzyme-linked immunosorbent assay (ELISA) tests. Blood levels of E2 and P4 were measured using chemiluminescence immunoassays. Results: Levels of PAI-2 from tears of pregnant women did not increase and did not correlate with gestation. Levels of PAI-2, E2 and P4 in blood significantly increased over gestation. Tear PAI-2 levels did not correlate with blood levels of PAI-2, E2 or P4. Although blood levels of PAI-1 increased with gestation, tear levels of PAI-1 were below the ELISA detection limit, similar to the situation for non-pregnant subjects. Conclusions: Tear PAI-2 levels are dissociated from the progression of pregnancy and the concomitant elevated systemic blood PAI-2, E2 and P4 levels, indicating the possibility of local control of proteolysis in the eye during pregnancy in the absence of wounding or surgery on the eye.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Gestation
Human Tears
Pregnancy
Proteolysis
Tear Enzymes
Megjelenés:International Journal of Ophthalmology & Eye Science. - 3 : 7 (2015), p. 121-125. -
További szerzők:Tőzsér József (1959-) (molekuláris biológus, biokémikus, vegyész) Silver, David M. Jakab Attila (1964-) (szülész-nőgyógyász, endokrinológus) Németh Gábor (1975-) (szemész) Berta András (1955-) (szemész, gyermekszemész) Csutak Adrienne (1971-) (szemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

7.

001-es BibID:BIBFORM040697
Első szerző:Tőzsér József (molekuláris biológus, biokémikus, vegyész)
Cím:Lactate dehydrogenase activity in pathological human tears obtained with glass capillaries correlates with the albumin content / Tözsér József, Berta András
Dátum:1998
ISSN:0165-5701
Megjegyzések:Lactate dehydrogenase (LDH) activity was measured in stimulated normal human tears and in tears from patients suffering from various corneal and conjunctival disorders. In normal tears the LDH activity was below the detection level of the method used, and it was hardly detectable in tears of most of the patients. The LDH activity correlated with the serum albumin content (r = 0.745, n = 32), suggesting that its source in pathological cases could be the plasma by transudation, and not the surface epithelial cells. Based on these results, LDH activity cannot be used as a measure of epithelial cell destruction in most pathological conditions, since the tear secretion of the patients is usually stimulated due to irritation, associated with the disorder or disease.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:International Ophthalmology. - 22 : 5 (1998), p. 289-292. -
További szerzők:Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1