1.

001-es BibID:bibEBI7505
Első szerző:Kuhn Ferenc
Cím:The continuous-injection technique to reduce complications during retrobulbar anesthesia / Kuhn F., Mester V., Berta A.
Dátum:1999
Megjegyzések:Retrobulbar as well as peribulbar anesthesia remain relatively risky procedures; retrobulbar hemorrhage and especially globe penetration or perforation can have blinding consequences. Our continuous-injection-technique greatly reduces these risks whether used for retrobulbar or peribulbar anesthesia. If the ophthalmologist starts injecting the agent while advancing the needle, the fluid pushes tissues away, possibly preventing a hemorrhage. Since resistance against the plunger is instantaneously experienced if the needle impacts the sclera, the ophthalmologist is adequately warned before actual perforation of the sclera occurs.
Tárgyszavak:idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Ophthalmic Surgery and Lasers. - 30 : 1 (1999), p. 67-68. -
További szerzők:Mester Viktória Berta András (1955-) (szemész, gyermekszemész)
Borító:

2.

001-es BibID:BIBFORM013629
Első szerző:Németh Gábor (szemész)
Cím:Comparison of anterior chamber depth measurements conducted with Pentacam HR(®) and IOLMaster(®) / G. Nemeth, Z. Hassan, L. Modis Jr., E. Szalai, K. Katona, A. Berta
Dátum:2011
ISSN:1542-8877
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Ophthalmic Surgery Lasers & Imaging. - 42 : 3 (2011), p. 144-147. -
További szerzők:Hassan, Ziad (1962-) (szemész) Módis László (1964-) (szemész szakorvos, kontaktológus) Szalai Eszter (1984-) (orvos) Katona Kristóf Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

3.

001-es BibID:BIBFORM013630
Első szerző:Szalai Eszter (orvos)
Cím:Anterior chamber depth measurements obtained with Pentacam HR(®) imaging system and conventional A-scan ultrasound / E. Szalai, A. Berta, G. Németh, Z. Hassan, L. Módis Jr.
Dátum:2011
ISSN:1542-8877
Megjegyzések:BACKGROUND AND OBJECTIVE: To evaluate the reliability and repeatability of anterior chamber depth (ACD) measurements obtained with the rotating Scheimpflug camera and conventional A-scan ultrasound. PATIENTS AND METHODS: The right eyes of 46 healthy volunteers were examined. ACD was determined first with the Pentacam HR (Oculus, Wetzlar, Germany) and then by ultrasound (AL-2000; Tomey, Tennenlohe, Germany). RESULTS: The mean ACD results were significantly shallower when obtained with the Pentacam HR (Investigator 1: 2.89 ± 0.41 mm; Investigator 2: 2.90 ± 0.41 mm) than with ultrasound (Investigator 1: 3.08 ± 0.43 mm, P < .0001; Investigator 2: 3.00 ± 0.45, P = .0005). Significant and strong correlation was observed between the two techniques (Investigator 1: r = 0.937; Investigator 2: r = 0.913). CONCLUSION: ACD measurements obtained with the Pentacam HR seemed to be reliable and repeatable when the cornea was optically clear. The significant differences between the Pentacam HR and ultrasound indicate that the two devices should not be used interchangeably for ACD measurements.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Ophthalmic Surgery Lasers & Imaging. - 42 : 3 (2011), p. 248-253. -
További szerzők:Berta András (1955-) (szemész, gyermekszemész) Németh Gábor (1975-) (szemész) Hassan, Ziad (1962-) (szemész) Módis László (1964-) (szemész szakorvos, kontaktológus)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító: