1.

001-es BibID:BIBFORM039991
Első szerző:Jánszky Imre
Cím:Demonstration of increasing standard pH value of lacrimal fluid with increase of flow rate / Janszky I., Vámosi P., Országh I., Berta A.
Dátum:2001
ISSN:1395-3907
Megjegyzések:To test the hypothesis that pH value of human tears is affected by flow rate. METHODS: After stimulation with a drop of 70% alcohol into the ipsilateral nasal cavity tears from the left eyes of 30 healthy volunteers were collected with glass capillaries while flow rate of tear secretion was registered. The pCO(2), actual and standard pH were determined in the collected samples with the Astrup method: Standard pH is defined as the pH of the sample that has been equilibrated at 37 degrees C with a gas mixture having pCO(2)=40 mmHg. RESULTS: The flow rate correlated positively and significantly with both the standard pH value (r=0.503, p<0.01) and the pCO(2) (r=0.517, p<0.01) while there was no correlation between the actual pH and the flow rate. CONCLUSION: Loss of CO(2) from the sample is a cause of serious uncertainty in tear pH determination. A positive flow rate-pH relationship was found for human tears when the uncertainty was removed by determination of the standard pH.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Acta Ophthalmologica Scandinavica. - 79 : 2 (2001), p. 180-183. -
További szerzők:Vámosi Péter (1964-) (szemorvos) Országh I. Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM049996
Első szerző:Vámosi Péter (szemorvos)
Cím:Comparison of different keratometers with the EyeSys videokeratoscope / Péter Vámosi, Zoltán Sohajda, László Modis, György Vámosi, András Berta
Dátum:1998
ISSN:1395-3907
Megjegyzések:We compared the accuracy and the reproducibility of the measurements using a Haag-Streit, a Shin-Nippon, and a Carl Zeiss keratometer and an EyeSys videokeratoscope. Two investigators performed 20 measurements on 3 calibrated steel balls and 5 measurements on 22 normal corneas with all instruments. Calculating the accuracy of the measurements the limits of the 95% confidence intervals of the bias were determined. The accuracy was better than +/-0.1D for the keratometers, whereas it was better than +/-0.25D for the EyeSys videokeratoscope. The coefficient of reproducibility (1.96 x standard deviation) on test balls and corneas was smaller than 0.25D in the case of the Shin-Nippon and Carl Zeiss keratometers and the EyeSys videokeratoscope whereas it was between 0.25-0.5D in the case of the Haag-Streit keratometer. The Carl Zeiss keratometer was the best with respect to the accuracy and reproducibility of the measurements. Paired t-test was used to find possible significant differences between the results of the two investigators, but only clinically insignificant differences were found.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Acta Ophthalmologica Scandinavica. - 76 : 2 (1998), p. 158-164. -
További szerzők:Sohajda Zoltán (1969-) (szemész) Módis László (1964-) (szemész szakorvos, kontaktológus) Vámosi György (1967-) (biofizikus) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat