1.

001-es BibID:BIBFORM013623
Első szerző:Németh Gábor (szemész)
Cím:A comparison of accommodation amplitudes in pseudophakic eyes measured with three different methods / Nemeth G., Tsorbatzoglou A., Vamosi P., Sohajda Z., Berta A.
Dátum:2008
ISSN:0950-222X
Megjegyzések:PURPOSE: To compare the accommodative amplitudes with three different methods in pseudophakic eyes with different types of intraocular lenses (IOLs). METHODS: Fifty-one pseudophakic eyes of 44 patients (age: 72.02+/-8.53 years) were studied. One of two different types of IOL were implanted (N=30, three-piece Alcon Acrysof MA60AC and N=21, one-piece Alcon Acrysof SA60AT) in-the-bag after standard phacoemulsification. The time of the examinations was 13.85+/-7.35 months postoperatively. We measured the amplitude of accommodation with three different methods: (1) subjective minus-lenses-to-blur method; (2) a new optical device (ACMaster, Carl Zeiss, Jena, Germany) using partial coherence interference (PCI) technique under physiological stimulus; and (3) objective anterior chamber depth measuring with a standard A-scan ultrasonic device (Ultrascan Imaging System, Alcon Laboratories, Forth Worth, TX, USA) before and after pharmacological relaxation of ciliary muscle. RESULTS: We measured -0.83+/-0.63 D amplitude of accommodation with subjective minus-lenses-to-blur method. The IOL position did not change significantly during physiological accommodation effort measured with PCI method (-0.026+/-0.134 mm). The change in the IOLs position between near fixating and after ciliary muscle relaxation was -0.18+/-0.28 mm measured with ultrasound. There were no significant differences between values of one-piece and three-piece IOL groups. CONCLUSION: The amplitude of accommodation measured by subjective and objective methods are different and are not comparable with each other. We did not observe any difference between values of examined two types of IOLs.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Eye. - 22 : 1 (2008), p. 65-69. -
További szerzők:Tsorbatzoglou, Alexis (1970-) (szemész) Vámosi Péter (1964-) (szemorvos) Sohajda Zoltán (1969-) (szemész) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

2.

001-es BibID:BIBFORM049767
Első szerző:Sohajda Zoltán (szemész)
Cím:Diódalézerrel (810 nm) szerzett kezdeti tapasztalatink a diabeteses maculopathia kezelésében / Sohajda Zoltán, Vámosi Péter, Berta András
Dátum:2002
Tárgyszavak:Orvostudományok Elméleti orvostudományok magyar nyelvű folyóiratközlemény hazai lapban
Megjelenés:Szemészet. - 139 (2002), p. 41-44. -
További szerzők:Vámosi Péter (1964-) (szemorvos) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM049996
Első szerző:Vámosi Péter (szemorvos)
Cím:Comparison of different keratometers with the EyeSys videokeratoscope / Péter Vámosi, Zoltán Sohajda, László Modis, György Vámosi, András Berta
Dátum:1998
ISSN:1395-3907
Megjegyzések:We compared the accuracy and the reproducibility of the measurements using a Haag-Streit, a Shin-Nippon, and a Carl Zeiss keratometer and an EyeSys videokeratoscope. Two investigators performed 20 measurements on 3 calibrated steel balls and 5 measurements on 22 normal corneas with all instruments. Calculating the accuracy of the measurements the limits of the 95% confidence intervals of the bias were determined. The accuracy was better than +/-0.1D for the keratometers, whereas it was better than +/-0.25D for the EyeSys videokeratoscope. The coefficient of reproducibility (1.96 x standard deviation) on test balls and corneas was smaller than 0.25D in the case of the Shin-Nippon and Carl Zeiss keratometers and the EyeSys videokeratoscope whereas it was between 0.25-0.5D in the case of the Haag-Streit keratometer. The Carl Zeiss keratometer was the best with respect to the accuracy and reproducibility of the measurements. Paired t-test was used to find possible significant differences between the results of the two investigators, but only clinically insignificant differences were found.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Acta Ophthalmologica Scandinavica. - 76 : 2 (1998), p. 158-164. -
További szerzők:Sohajda Zoltán (1969-) (szemész) Módis László (1964-) (szemész szakorvos, kontaktológus) Vámosi György (1967-) (biofizikus) Berta András (1955-) (szemész, gyermekszemész)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

4.

001-es BibID:BIBFORM049752
Első szerző:Vámosi Péter (szemorvos)
Cím:A comparison of two different cornea topographs / P. Vámosi, Z. Sohajda
Dátum:1997
ISBN:9634080650
Tárgyszavak:Orvostudományok Elméleti orvostudományok előadáskivonat
Megjelenés:SOE '97 : XIth Congress of the European Society of Ophthalmology : Budapest, June 1-5, 1997 : final programme and abstract book / [organizing comm. Béla Alberth et al.] - p. 302. -
További szerzők:Sohajda Zoltán (1969-) (szemész)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat