CCL

Összesen 6 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM015699
Első szerző:Hegyesi Gyula (villamosmérnök)
Cím:Ethernet Based Distributed Data Acquisition System for a Small Animal PET / Gy. Hegyesi, J. Imrek, G. Kalinka, J. Molnár, D. Novák, J. Végh, L. Balkay, M. Emri, S. A. Kis, G. Molnár, L. Trón, I. Valastyán, I. Bagaméry, T. Bükki, S. Rózsa, Zs. Szabó, A. Kerek
Dátum:2006
ISSN:0018-9499
Megjegyzések:We report on the design of a small animal PET scanner being developed at our institutes. The existing setup is the first version of the miniPET machine consisting of four detector modules. Each detector module consists of an 8times8 LSO scintillator crystal block, a position sensitive photomultiplier, a digitizer including a digital signal processing board and an Ethernet interface board. There is no hardware coincidence detection implemented in the system and coincidence is determined based on a time stamp attached to every event by a digital CFD algorithm. The algorithm is implemented in the digital signal processing board and generates a time stamp with a coincidence resolution of less than 2 ns. The data acquisition system is based on Ethernet network and is highly scalable in size and performance
Tárgyszavak:Műszaki tudományok Villamosmérnöki tudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Ieee Transactions On Nuclear Science 53 : 4 (2006), p. 2112-2117. -
További szerzők:Imrek József (1980-) Kalinka Gábor Molnár József (1954-) (villamosmérnök) Novák Dezső Imre (1971-) (villamosmérnök) Végh János (1953-) (fizikus) Balkay László (1963-) (biofizikus) Emri Miklós (1962-) (fizikus) Kis Sándor Attila (1973-) (fizikus) Molnár Gergely (1979-) (informatikus) Trón Lajos (1941-) (biofizikus) Valastyán Iván (1979-) (fizikus, informatikus) Bagaméry István Bükki Tamás Rózsa Sándor (villamosmérnök) Szabó Zsolt (1963-) (fizikus) Kerék András (fizikus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM018666
Első szerző:Imrek József
Cím:Development of an FPGA-based data acquisition module for small animal PET / J. Imrek, D. Novák, Gy. Hegyesi, G. Kalinka, J. Molnár, J. Végh, L. Balkay, M. Emri, G. Molnár, L. Trón, I. Bagaméry, T. Bükki, S. Rózsa, Zs. Szabó, A. Kerek
Dátum:2006
ISSN:0018-9499
Megjegyzések:Abstract: We report on the design of a data acquisition (DAQ) module for a small animal PET camera developed at our institutes. During the design an important guideline was to develop a system which is built up from strictly identical DAQ modules, and which has no built-in hardware limitation on the maximum number of modules. The developed DAQ module comprises of an LSO scintillator crystal block, a position sensitive PMT, analog signal conditioning circuits, a digitizer, an field programmable gate array (FPGA) for digital signal processing, and a communication module through which the collected data are sent to a cluster of computers for postprocessing and storage. Instead of implementing hardware coincidence detection between the modules, we attach a precise time stamp to each event in our design, and the coincidence is determined by the data collecting computers during postprocessing. The digital CFD algorithm implemented in the FPGA gives a time resolution of 2 ns FWHM for real detector signals.
Tárgyszavak:Orvostudományok Klinikai orvostudományok konferenciacikk
Megjelenés:IEEE Transactions on Nuclear Science. - 53 : 5 (2006), p. 2698-2703. -
További szerzők:Novák Dezső Imre (1971-) (villamosmérnök) Hegyesi Gyula (1963-) (villamosmérnök) Kalinka Gábor Molnár József (1954-) (villamosmérnök) Végh János (1953-) (fizikus) Balkay László (1963-) (biofizikus) Emri Miklós (1962-) (fizikus) Molnár Gergely (1979-) (informatikus) Trón Lajos (1941-) (biofizikus) Bagaméry István Bükki Tamás Rózsa Sándor (villamosmérnök) Szabó Zsolt (1963-) (fizikus) Kerék András (fizikus)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

3.

001-es BibID:BIBFORM015791
Első szerző:Kis Sándor Attila (fizikus)
Cím:Performance test of the MiniPET-II small animal scanner according to the NEMA NU-4 standard / S. A. Kis, I. Lajtos, M. Emri, L. Tron, G. Opposits, T. Bükki, Gy. Hegyesi, J. Imrek, I. Valastyán, J. Molnár, D. Novák, L. Balkay
Dátum:2009
Megjegyzések:A full ring small animal PET camera (MiniPET-II) has been built in our institute as part of an R+D project. In this work we determined the performance parameters of the MiniPET-II scanner. The measurements and data evaluation for this purpose were based on the National Electrical Manufacturers Association (NEMA) NU-4 standards. The spatial resolution varies between 1.4 to 2.1 mm from central to 25 mm radial distances. The system sensitivity was 1.14%. The counting rate capability, expressed in noise equivalent counting rate (NEC), was shown to peak of over 55.1 kcps at 38.9 MBq using a mouse phantom. The scatter fraction with the same acquisition was 12.3%. Evaluations of image quality and quantization accuracy were also performed using the NEMA NU-4 required image-quality phantom and animal studies. The study proved that the MiniPET-II scanner has a good imaging capability and ability to perform real animal studies.
ISBN:978-1-4244-3961-4
Tárgyszavak:Orvostudományok Elméleti orvostudományok tanulmány, értekezés
Megjelenés:Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE / eds. Bukki, T., Hegyesi, G., Imrek, J., Valastyan, I., Molnar, J., Novak, D., Balkay, L. - p. 3185-3189. -
További szerzők:Lajtos Imre (1986-) (fizikus) Emri Miklós (1962-) (fizikus) Trón Lajos (1941-) (biofizikus) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Bükki Tamás Hegyesi Gyula (1963-) (villamosmérnök) Imrek József (1980-) Valastyán Iván (1979-) (fizikus, informatikus) Molnár József (1954-) (villamosmérnök) Novák Dezső Imre (1971-) (villamosmérnök) Balkay László (1963-) (biofizikus)
Internet cím:Szerző által megadott URL
Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

4.

001-es BibID:BIBFORM001568
Első szerző:Kis Sándor Attila (fizikus)
Cím:Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner / S. A. Kis, M. Emri, G. Opposits, T. Bükki, I. Valastyán, Gy. Hegyesi, J. Imrek, G. Kalinka, J. Molnár, D. Novák, J. Végh, A. Kerek, L. Trón, L. Balkay
Dátum:2007
Megjegyzések:In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
Tárgyszavak:Műszaki tudományok Orvostudományok Informatikai tudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Nuclear Instruments & Methods In Physics Research Section A-Accelerators Spectrometers Detectors And Associated Equipment 571 : 1-2 (2007), p. 449-452. -
További szerzők:Emri Miklós (1962-) (fizikus) Opposits Gábor (1974-) (fizikus, szoftver fejlesztő) Bükki Tamás Valastyán Iván (1979-) (fizikus, informatikus) Hegyesi Gyula (1963-) (villamosmérnök) Imrek József (1980-) Kalinka Gábor Molnár József (1954-) (villamosmérnök) Novák Dezső Imre (1971-) (villamosmérnök) Végh János (1953-) (fizikus) Kerék András (fizikus) Trón Lajos (1941-) (biofizikus) Balkay László (1963-) (biofizikus)
Internet cím:elektronikus változat
elektronikus változat
DOI
Borító:

5.

001-es BibID:BIBFORM037251
Első szerző:Magdics Milán
Cím:Performance Evaluation of Scatter Modeling of the GPU-based "Tera-Tomo" 3D PET Reconstruction / Magdics M., Szirmay-Kalos L., Tóth B., Légrády D., Cserkaszky A., Balkay L., Domonkos B., Völgyes D., Patay G., Major P., Lantos J., Bükki T.
Dátum:2011
Megjegyzések:In positron emission tomography (PET), photon scattering inside the body causes significant blurring and quantification error in the reconstructed images. To solve this problem we have developed Monte Carlo (MC) based 3D PET reconstruction algorithms implemented on the Graphics Processing Unit (GPU). Our implementation takes multiple Compton scattering into account without any significant additional cost. The performance of the scatter correction is evaluated using GATE simulation as well as by comparing reconstruction results of Tera-Tomo to the reference reconstruction implementation of the Philips Gemini TOF PET which applies attenuation correction and single scatter simulation (SSS) for scatter correction. The comparative reconstruction results are based on the NEMA NU2- 2007 image quality phantom.
Tárgyszavak:Orvostudományok Klinikai orvostudományok konferenciacikk
Megjelenés:IEEE Nuclear Science Symposium. - 1 (2011), p. 4086-4088. -
További szerzők:Szirmay-Kalos László Tóth Balázs Légrády Dávid Cserkaszky Áron Balkay László (1963-) (biofizikus) Domonkos Balázs Völgyes Dávid Patay Gergely Major Péter Lantos Judit Bükki Tamás
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
DOI
Borító:

6.

001-es BibID:BIBFORM003213
Első szerző:Valastyán Iván (fizikus, informatikus)
Cím:Full 3-D cluster-based iterative image reconstruction tool for a small animal PET camera / Valastyán I., Imrek J., Molnár J., Novák D., Balkay L., Emri M., Trón L., Bükki T., Kerék A.
Dátum:2007
Megjegyzések:Iterative reconstruction methods are commonly used to obtain images with high resolution and good signal-to-noise ratio in nuclear imaging. The aim of this work was to develop a scalable, fast, cluster based, fully 3-D iterative image reconstruction package for our small animal PET camera, the miniPET. The reconstruction package is developed to determine the 3-D radioactivity distribution from list mode type of data sets and it can also simulate noise-free projections of digital phantoms. We separated the system matrix generation and the fully 3-D iterative reconstruction process. As the detector geometry is fixed for a given camera, the system matrix describing this geometry is calculated only once and used for every image reconstruction, making the process much faster. The Poisson and the random noise sensitivity of the ML-EM iterative algorithm were studied for our small animal PET system with the help of the simulation and reconstruction tool. The reconstruction tool has also been tested with data collected by the miniPET from a line and a cylinder shaped phantom and also a rat.
Tárgyszavak:Orvostudományok Elméleti orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:Nuclear Instruments and Methods in Physics Research 571 : 1-2 (2007), p. 219-222. -
További szerzők:Imrek József (1980-) Molnár Jenő (1912-1984) (urológus) Novák D. Balkay László (1963-) (biofizikus) Emri Miklós (1962-) (fizikus) Trón Lajos (1941-) (biofizikus) Bükki Tamás Kerék A.
Internet cím:elektronikus változat
DOI
elektronikus változat
Borító:
Rekordok letöltése1