1.

001-es BibID:BIBFORM031908
035-os BibID:PMID:7478396
Első szerző:Benyounes, H.
Cím:Superimposition of PET images using 18F-fluorodeoxyglucose with magnetic resonance images in patients with pancreatic carcinoma / Benyounes H., Smith F. W., Campbell C., Evans N. T., Norton M. Y., Mikecz P., Heys S. D., Bruce D., Eremin O., Sharp P. F.
Dátum:1995
ISSN:0143-3636
Megjegyzések:Six patients with histologically proven adenocarcinoma of the pancreas were studied using 2-deoxy-2-[18F]-fluoro-D-glucose (18F-FDG) using positron emission tomography (PET), and magnetic resonance imaging (MRI). In all six cases there was avid accumulation of 18F-FDG within the pancreatic tumour and clear visualization of the tumour on the MRI images. Delineation of the tumours was aided by superimposition of the images from the two imaging methods, which was achieved by using a system of surface markers.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
külföldön készült közlemény
Megjelenés:Nuclear Medicine Communications. - 16 : 7 (1995), p. 575-580. -
További szerzők:Smith, Frank W. Campbell, Cabrina Evans, Noel T. S. Norton, M. Heys, S. D. Bruce, D. Eremin, O. Sharp, Peter F. Mikecz Pál (1956-) (vegyész)
Internet cím:Szerző által megadott URL
DOI
Borító:

2.

001-es BibID:BIBFORM031905
035-os BibID:WOS:000077624500023
Első szerző:Welch, A. E.
Cím:Attenuation correction in PET using consistency information / Welch, A., Campbell, C., Clackdoyle, R., Natterer, F., Hudson, M., Bromiley, A., Mikecz, P., Chillcot, F., Dodd, M., Hopwood, P., Craib, S., Gullberg, G. T., Sharp, P.
Dátum:1998
ISSN:0018-9499
Megjegyzések:In this study the authors use the consistency conditions of the Radon transform to aid attenuation correction in PET. The conditions are used both for estimating the parameters of a uniform elliptical attenuation distribution (without any transmission measurements) and for correcting for patient motion between the transmission and emission acquisitions. The results show that, for a uniform elliptical attenuation distribution, the reconstructed count densities obtained using attenuation correction based on the consistency conditions are within 1% of the true values. The method is shown to be fairly tolerant to the effects of photon counting statistics and to small non-uniformities in the attenuation distribution (such as skull attenuation). The results also show that the consistency conditions may be useful in correcting for patient motion. The method is shown to effectively compensate for shifts in two dimensions using both simulated and experimental data
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
külföldön készült közlemény
Megjelenés:IEEE transactions on nuclear science. - 45 : 6 (1998), p. 3134-3141. -
További szerzők:Campbell, Cabrina Clackdoyle, R. Natterer, F. Hudson, M. Bromiley, A. Chillcot, F. Dodd, Maurice Hopwood, P. Craib, S. Gullberg, G. T. Sharp, Peter F. Mikecz Pál (1956-) (vegyész)