CCL

Összesen 1 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM118127
035-os BibID:(cikkazonosító)13020215 (WoS)001152827800001 (Scopus)85183116796
Első szerző:Irfan, Muhammad
Cím:Comparative Phytotoxicity of Metallic Elements on Duckweed Lemna gibba L. Using Growth- and Chlorophyll Fluorescence Induction-Based Endpoints / Muhammad Irfan, Ilona Mészáros, Sándor Szabó, Viktor Oláh
Dátum:2024
ISSN:2223-7747
Megjegyzések:In this study, we exposed a commonly used duckweed species-Lemna gibba L.-to twelve environmentally relevant metals and metalloids under laboratory conditions. The phytotoxic effects were evaluated in a multi-well-plate-based experimental setup by means of the chlorophyll fluorescence imaging method. This technique allowed the simultaneous measuring of the growth and photosynthetic parameters in the same samples. The inhibition of relative growth rates (based on frond number and area) and photochemical efficiency (F-v/F-o and Y(II)) were both calculated from the obtained chlorophyll fluorescence images. In the applied test system, growth-inhibition-based phytotoxicity endpoints proved to be more sensitive than chlorophyll-fluorescence-based ones. Frond area growth inhibition was the most responsive parameter with a median EC50 of 1.75 mg L-1, while F-v/F-o, the more responsive chlorophyll-fluorescence-based endpoint, resulted in a 5.34 mg L-1 median EC50 for the tested metals. Ag (EC50 0.005-1.27 mg L-1), Hg (EC50 0.24-4.87 mg L-1) and Cu (EC50 0.37-1.86 mg L-1) were the most toxic elements among the tested ones, while As(V) (EC50 47.15-132.18 mg L-1), Cr(III) (EC50 6.22-19.92 mg L-1), Se(VI) (EC50 1.73-10.39 mg L-1) and Zn (EC50 3.88-350.56 mg L-1) were the least toxic ones. The results highlighted that multi-well-plate-based duckweed phytotoxicity assays may reduce space, time and sample volume requirements compared to the standard duckweed growth inhibition tests. These benefits, however, come with lowered test sensitivity. Our multi-well-plate-based test setup resulted in considerably higher median EC50 (3.21 mg L-1) for frond-number-based growth inhibition than the 0.683 mg L-1 median EC50 derived from corresponding data from the literature with standardized Lemna-tests. Under strong acute phytotoxicity, frond parts with impaired photochemical functionality may become undetectable by chlorophyll fluorometers. Consequently, the plant parts that are still detectable display a virtually higher average photosynthetic performance, leading to an underestimation of phytotoxicity. Nevertheless, multi-well-plate-based duckweed phytotoxicity assays, combined with chlorophyll fluorescence imaging, offer definite advantages in the rapid screening of large sample series or multiple species/clones. As chlorophyll fluorescence images provide information both on the photochemical performance of the test plants and their morphology, a joint analysis of the two endpoint groups is recommended in multi-well-plate-based duckweed phytotoxicity assays to maximize the information gained from the tests.
Tárgyszavak:Természettudományok Biológiai tudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
békalencse
fitotoxicitás
ökotoxikológia
növekedésgátlás
klorofill fluoreszcencia indukció
nehézfém
Megjelenés:Plants-Basel. - 13 : 2 (2024), p. 1-16. -
További szerzők:Mészáros Ilona (1952-) (biológus) Szabó Sándor (biológus) Oláh Viktor (1980-) (biológus)
Pályázati támogatás:FK 134296
OTKA
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1