CCL

Összesen 1 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM094394
035-os BibID:(cikkazonosító)110234
Első szerző:Renew, J. Ross
Cím:Comparison of the TetraGraph and TOFscan for monitoring recovery from neuromuscular blockade in the Post Anesthesia Care Unit. / Renew J. R., Hernandez-Torres V., Logvinov I., Nemes R., Nagy G., Li Z., Watt L., Murphy G. S.
Dátum:2021
ISSN:0952-8180
Megjegyzések:Study objective: Comparison of the TetraGraph (TG) and TOFscan (TS) for monitoring recovery from neuromuscular blockade in the Post Anesthesia Care Unit (PACU). Design: Randomized, multicenter trial. Setting: PACU in three tertiary care hospitals. Patients: 120 patients (40 per site) receiving neuromuscular blockade during elective surgery. Interventions: Patients were enrolled preoperatively and intraoperative neuromuscular blockade management was at the discretion of the anesthesiologist. Upon arrival to the PACU, patients were randomized to have either TG or TS placed on their dominant hand. The alternate device (TS or TG) was placed on the nondominant hand. Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis was measured. Measurements: Train-of-four ratios (TOFRs) were obtained upon arrival to the PACU (t = 0), after 5 min (t = + 5) and after +10 min (t = + 10). Main results: There was there was no significant difference in the mean TOFRs obtained with the TG and TS at t = 0 (0.97 ? 0.18 vs 0.94 ? 0.13, P = 0.06, respectively) and t = + 5 (0.96 ? 0.20 vs 0.95 ? 0.12, P = 0.29, respectively). At (t = + 10), there was a statistically significant difference in mean TOFRs obtained with the TG and TS, (0.99 ? 0.14 vs 0.94 ? 0.12, P < 0.001, respectively). The bias between devices at t = 0 was estimated to be 0.03 (95% CI, ?? 0.29 to 0.35, P = 0.26); at t = + 5 min, it was estimated to be 0.02 (95% CI, ?? 0.36 to 0.40, P = 0.54); and at t = +10 min, it was estimated to be 0.05 (95% CI, ?? 0.25 to 0.36, P = 0.77). Conclusions: TS and TG provide interchangeable quantitative measurements once the TOF ratio has returned to a value of 0.90 or greater in the PACU.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Journal Of Clinical Anesthesia. - 71 (2021), p. 1-6. -
További szerzők:Hernandez-Torres, Vivian Logvinov, Ilana I. Nemes Réka (1985-) (aneszteziológus, intenzív terápiás szakorvos) Nagy György (1986-) (aneszteziológus, intenzív terápiás szakorvos) Li, Zhuo Watt, Liah Murphy, Glenn S.
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1