CCL

Összesen 3 találat.
#/oldal:
Részletezés:
Rendezés:

1.

001-es BibID:BIBFORM101269
035-os BibID:(WoS)000778960800003 (Scopus)85127403337
Első szerző:Csernátony Zoltán (ortopéd sebész, traumatológus)
Cím:The roof step cut : a novel technique for bony reconstruction of acetabular roof deficiency during total hip replacement / Csernátony Zoltán, Győrfi Gyula, Barna Sándor, Manó Sándor, Szabó János, Zhang Lei
Dátum:2022
ISSN:2687-4784 2687-4792
Megjegyzések:Objectives: This study aims to present a new technique, the roof step cut (RSC), for acetabular augmentation of hip dysplasia. Patients and methods: Between December 2008 and March 2020, we applied the RSC technique in a total of 48 hips of 41 patients (2 males, 39 females; mean age: 50.1 +/- 9.5 years; range, 30 to 75 years) with Hartofilakidis type A, B, C hip dysplasia. The RSC technique uses a L-shaped graft cut from the femoral head. The graft is partially inside the acetabulum and partially on the lateral aspect of the ilium. It is fixed with two screws at a 45 degrees angle allowing simultaneous distalization and lateral covering of the cementless cup. Follow-up was done at six weeks, three months, and annually thereafter using standard pelvis anteroposterior X-ray and function scores. The 99mTc bone scintigraphy examination was also performed at around two weeks, six months, and 12 months postoperatively to evaluate the healing process of the graft. Results: The mean follow-up time was 59.6 +/- 25.6 (range, 12 to 109) months. No significant center-edge angle changes and no contiguous radiolucent zones at the bone prosthesis interface were observed at the final follow-up. The single-photon emission tomography (SPECT) showed the activity of the bone graft gradually increased after surgery and became almost the same as the reference area after 12 months. Functional evaluation showed a significant improvement after the operation. No complication directly related to the technique was observed. Conclusion: In the short-term follow-up, the RSC technique is a reliable procedure for acetabular augmentation of hip dysplasia, providing enough coverage for the cementless cup and assuring proper stability.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
folyóiratcikk
Megjelenés:Joint Diseases and Related Surgery. - 33 : 1 (2022), p. 9-16. -
További szerzők:Győrfi Gyula (1982-) (orvos) Barna Sándor (1982-) (kutató orvos) Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök) Szabó János (1966-) (ortopéd sebész) Zhang, Lei (1988-) (orvos)
Pályázati támogatás:Bridging Fund 2021 University of Debrecen, Faculty of Medicine
Egyéb
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

2.

001-es BibID:BIBFORM047999
Első szerző:Szabó János (ortopéd sebész)
Cím:The biological and biomechanical comparison of two bulk bone graft techniques used in case of dysplastic acetabulum / János Szabó, Sándor Manó, Ádám Lőrincz, Gyula Győrfi, László Kiss, Zoltán Csernátony
Dátum:2014
ISSN:1633-8065 1432-1068
Megjegyzések:AbstractBackground The incorporation of bulk bone grafts in thereplacement of dysplastic acetabulum is determined by thebiological environment of the recipient site, the size of thecontact surface, and the stability of the osteosynthesis used.Based on these, the present study compares the Harrisacetabular plasty used routinely by us with the Radojevic?L-shaped graft technique.Methods For our measurements, we used 20 hemi-pelvisesremoved from 10 cadavers. In 10 cases, acetabularplasty according to Harris, in 10 cases Radojevic? L-plasty,was performed. The biological environment was analyzed;with geometric calculations, the contact surface wasdetermined, and with a material testing apparatus, theprimary stability of the osetosynthesis was measured. Forthe measurements, a new method was developed.Results The Radojevic? technique provides a better biologicalenvironment for graft ingrowth. The contact surfaceis nearly twice as much as in Harris plasty. No significantdifference was found in the primary stability of the osteosynthesisused. The deviation on the value of the stabilitymeasurements is explained by the differences in the bonequality of the cadavers used.Conclusions Based on the 3 aspects examined, the Radojevic? L-shaped graft technique has similar stability whencompared to the Harris acetabular plasty, but providesbetter biological circumstances and larger graft host bonecontact. Based on this, we started using the L-shapedtechnique in our department.
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény külföldi lapban
Megjelenés:European Journal of Orthopaedic Surgery and Traumatology. - 24 : 5 (2014), p. 679-684. -
További szerzők:Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök) Lőrincz Ádám Győrfi Gyula (1982-) (orvos) Kiss László (1978-) (ortopéd sebész, traumatológus) Csernátony Zoltán (1959-2023) (ortopéd sebész, traumatológus)
Internet cím:Szerző által megadott URL
DOI
Intézményi repozitóriumban (DEA) tárolt változat
Borító:

3.

001-es BibID:BIBFORM042724
Első szerző:Szabó János (ortopéd sebész)
Cím:Instrument development for acetabular roof plasty in case of dysplastic acetabular replacement / János Szabó, Sándor Manó, Ádám Lőrincz, Gyula Győrfi, László Kiss
Dátum:2012
Tárgyszavak:Orvostudományok Klinikai orvostudományok idegen nyelvű folyóiratközlemény hazai lapban
egyetemen (Magyarországon) készült közlemény
Megjelenés:Biomechanica Hungarica. - 5 : 1 (2012), p. 31-38. -
További szerzők:Manó Sándor (1977-) (gépészmérnök, számítógépes tervezőmérnök) Lőrincz Ádám Győrfi Gyula (1982-) (orvos) Kiss László (1978-) (ortopéd sebész, traumatológus)
Internet cím:Intézményi repozitóriumban (DEA) tárolt változat
Borító:
Rekordok letöltése1